Minolta Di251f Service Manual page 65

Hide thumbs Also See for Di251f:
Table of Contents

Advertisement

Tech. Rep. Mode - Fax Set
Touch Panel Display
Port/Line
Port
Line
Stamp
Soft Switch Set
Terminal TX
Setting (The default is
Setting per port type.
Display
Single
G3 type system
Multi
If the system has G3 Multi-Pore Option
Setting per line type.
• Single: PSTN1
• Multi : PSTN1 or PSTN2
Used to indicate when the TX marker option is installed.
ON
This sets up the soft switches for maintenance.
• Procedure
1. Touch "Mode Selection".
2. Type the value for a mode of the soft switch and then touch
"Enter".
3. Touch "Bit Selection" or "HEX Selection".
4. Type the value of the soft switch with the 10-key pad and
then touch "Enter". Use <0> and <1> of the 10-key pad to
type bit values. For hex numbers, use 0-9, A, B, C, D, E, and
F.
5. The last "Enter" returns to the screen of the maintenance
menu.
You can receive data on the one touch dial or send the data
stored in the system to the call center.
• Procedure
1. Enter "Function ID Code" and "Extended ID Code" on the
screen of the terminal transmission and touch "Execute".
2. Start remote diagnostics on the screen of the remote diag-
nostics.
When the service call is in the data transmission mode, the
same call number will be used to make a terminal transmission
to the call center.
The service call is in the fax transmission mode, you need to
switch it to the data transmission mode and also change the
call number. Always restore the service call setup after you
complete a terminal transmission.