MODE 049
Factory setting bit : 0 0 0 0 1 1 0 1 (Hex : 0D)
Bit
Feature
765
432
Select upper limit of
10
transmission speed. (TX)
MODE 050
Factory setting bit : 0 0 0 0 1 1 0 1 (Hex : 0D)
Bit
Feature
765
432
Select upper limit of
10
transmission speed. (RX)
Logic
Meaning
000
Fixed to "000"
00000
2400 bps
00001
4800 bps
00010
7200 bps
00011
9600 bps
00100
12.0 kbps
00101
14.4 kbps
00110
16.8 kbps
00111
19.2 kbps
01000
21.6 kbps
01001
24.0 kbps
01010
26.4 kbps
01011
28.8 kbps
01100
31.2 kbps
01101
33.6 kbps
Others Not available
Logic
Meaning
000
Fixed to "000"
00000
2400 bps
00001
4800 bps
00010
7200 bps
00011
9600 bps
00100
12.0 kbps
00101
14.4 kbps
00110
16.8 kbps
00111
19.2 kbps
01000
21.6 kbps
01001
24.0 kbps
01010
26.4 kbps
01011
28.8 kbps
01100
31.2 kbps
01101
33.6 kbps
Others Not available
S-63
Description
• Need to disable "V.34
capability (MODE 048
Bit 2)" by setting "No" for
2400 bps.
• 16.8 kbps or faster is
valid only when "Allow
V.34? (MODE 048 Bit 2)"
is enabled (Yes).
Description
• Need to disable "V.34
capability (MODE 048
Bit 2)" by setting "No" for
2400 bps.
• 16.8 kbps or faster is
valid only when "Allow
V.34? (MODE 048 Bit 2)"
is enabled (Yes).

Advertisement