電機堵轉保護
Motor
ER-04
locked rotor
protection
硬體過流保護
Hardware
ER-05
overcurrent
protection
串口通訊超時
Serial
ER-07
Communication
Timeout
記憶體不良
ER-09
Memory error
光眼控制線路
故障
ER-10
Sensor control
line error
P20
1:縫紉機過重或堵死
2:電機超載
3:電機 4 線驅動線沒連接好或插
1: Sewing machine is overweight
or blocked
2: Motor overload
3: Motor 4 wire drive line is not
connected well or inserted
oppositely
1:縫紉機過重或堵死
2:電機超載
3:電機相位信號線沒連接好
1: Sewing machine is overweight
or blocked
2: Motor overload
3: Motor phase signal line is not
connected well
1:顯示幕連接主機板線連接不良
2:主機板晶片損壞
1: Connect error between display
panel and mainboard
2: Mainboard chip damage
1: 主機板記憶體損壞或不良
1: Memory on mainboard
damage or error
1: 顯示幕連結光眼線路不良
1: Connect error between display
panel and sensor.
1:檢查電機 4p 線
2:檢查縫紉機是否過重
3:更換控制器
1: Check motor 4p line
2: Check whether sewing
machine is overweight
3: Replace the control box
1:檢查顯示幕與控制器連接線
2:檢查控制器是否還可運行,
如不能運行就是控制器損壞
3:檢查機器旁是否有高頻機器
干擾
4:更換顯示幕
1:Check the connection line
between display panel and
control box.
2: Check whether the controller
run well.If not, controller
damage
3: Check whether there is a high
frequency machine near the
machine interference
4: Change display panel
1:控制器損壞
1: Control box damage
1:顯示幕損壞
2:顯示幕背部光眼連接線接觸
不良
1: Display panel damage
2:Connect error between
display panel and sensor

Advertisement