故障代碼解析
故障代碼
故障描述
Fault code
Fault description
找不到停針位
Can not find
ER-01
the position of
stop pin
調速器信號錯
ER-02
Governor
signal error
電機相位信號
錯誤
ER-03
Motor phase
signal error
ERROR CODE ANALYSIS
故障產生原因
Causes of failure
1: 手輪和電機靠的不夠近
2:手輪上磁鋼脫落
3:手輪磁鐵極性裝反
4:九針端子頭接觸不良
5:電機霍爾損壞
1: Hand wheel and motor is not
close enough.
2: Magnetic on hand wheel
separates
3: Hand wheel magnet polarity is
wrong
4: Contact error for 9-pin
connector.
5: Motor holzer damage
1:開機時沒插調速器
2:調速器插反
3:調速器線斷開
4:調速器損壞
1: Boot up without connecting
governor
2: Governor connects opposite
3: Governor line damage
4: Governor damage
1:九針插頭接觸不良
2:電機安裝時霍爾和轉子存在大
偏差
3:電機霍爾損壞
1: Contact error for 9-pin
connector
2: Serious installation deviation
between holzer and rotor
3: Motor holzer damage
Introduction
故障的解決方法
Fault solution
1:檢查電機信號線有無鬆動
2:更換手輪
3:更換電機
1 : Check whether the motor
signal line is loose
2: Replace hand wheel
3: Replace the motor
1:檢查調速器信號線
2:更換調速器
3:更換控制箱
1: Check the governor signal
line
2: Replace the governor
3: Replace control box
1:打開電機上的橡皮蓋通過孔
看電機轉子與定子是否在同
一平面保障誤差不超過 1mm
2:更換電機
3:更換控制箱
1: Open the rubber cover on
the motor. See whether the
motor rotor and stator in the
same plane and ensure the
deviation is no more than
1mm
2:Replace the motor
3: Replace the control box