Start-Up

Purpose
This section contains the necessary steps required to prepare the Bioshield™ UV Disinfection System for proper
operation.
Frequency
Required with new construction, retro-fit or replacement of outdated equipment.
Parts and Required Equipment
• Personal Safety Equipment
General risk due to pressurized piping and UV Vessel!
General risk due to electricity!
Hydraulic shock (water hammer) may occur as a result of improper use of valve(s) or trapped air inside the vessel.
Hydraulic shock and trapped air can damage the vessel.
Trapped air or no-flow situations may damage the vessel and/or the UV lamps due to overheating.
Procedure
1.
Confirm that all personnel operating this UV system have thoroughly reviewed these instructions prior to operating.
2.
Remove all dirt/debris from power supply enclosure, vessel and installation area resulting from installation activities.
3.
Inspect all plumbing connections and immediate plumbing network to ensure safe start-up.
4.
Inspect the vessel's Quartz Sleeve Module Faceplate to ensure proper assembly.
5.
Inspect quartz sleeve assemblies (Quartz Sleeve Retaining Nuts) confirming that they are tight.
6.
Inspect Power Supply Enclosure, confirm that it has been mounted properly and input power is in accordance with
local ordinances and codes.
7.
Inspect all sensors ensuring that the probes are properly installed in the vessel and Water Tight Connectors are
properly connected to their respective Power Supply Enclosure ports.
8. Verify that a successful Water Test has been completed. See Page 16 for instructions.