The following options appear on the SETUP Text Display. Four lines of text are viewed on the screen at a given time. Use
the "Right" key to advance the arrow (">") through the SETUP options. Use the "Enter" key to select the desired SETUP
option. Use the "Left" key to return to the MAIN UV System Text Display. Use the "Enter" key to select the desired SETUP
option.
Initializing Commands/Settings
Use the "Right" key (">") to change increment numbers by a factor of one and change NO to YES and YES to NO. The "Big
Left" and "Big Right" arrow keys will increment or decrement numbers by a greater amount. Pressing the "Enter" key will
accept your adjustments, then return you to the SETUP Menu Text Display.
Voltage Range
Displays the Factory-set "Low - Hi" Voltage set-points as well as the actual input
voltage
(YYY/incoming AC voltage). The UV System will not operate properly if operated
outside the Voltage set-point range. Damage may incur to ballasts and lamps if the
UV System is operated outside of the Voltage set-point range. DO NOT OPERATE
THE UV SYSTEM UNDER "OUT OF RANGE" CONDITIONS.
Temperature Hi
Displays the Factory set UV Vessel "Hi Water Temperature" and "Box (Power Sup-
ply Enclosure) "Hi Air Temperature" set-points. Both the "actual" vessel's water and
the enclosure's air temperature (YYY) are displayed.
SETUP Options
1.) Reset Hour Counter
1A.) Rest Master Counter
1B.) Reset Single Lamp
1C.) Reset All Lamps
2.) Scale UV
3.) Set UV Low Alarm
The following are brief descriptions of SETUP options. Press the "Left" key to
return to the SETUP Menu Text Display for list of options. Once the Text Display
returns to the SETUP Menu, press the "Left" key again to return to the MAIN UV
System Text Display. If a command is not initiated by using either key within a
couple of minutes the system will automatically revert to the MAIN UV System
Text Display.