SD card real time Data Recorder
+ Type K/J thermometer, Air flow
ANEMOMETER
Model : AM-4233SD
OPERATION MANUAL
Your purchase of this
ANEMOMETER &
THERMOMETER with
SD CARD DATA LOGGER
marks a step forward for you
into the field of
precision measurement.
Although this meter a
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.

Advertisement

Table of Contents
loading

Summary of Contents for Lutron Electronics AM-4233SD

  • Page 1 SD card real time Data Recorder + Type K/J thermometer, Air flow ANEMOMETER Model : AM-4233SD Your purchase of this ANEMOMETER & THERMOMETER with SD CARD DATA LOGGER marks a step forward for you into the field of precision measurement.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. FEATURES......................2. SPECIFICATIONS.................... 3. FRONT PANEL DESCRIPTION..............4. MEASURING PROCEDURE................4-1 Function selection ....................4-2 Air velocity/Temp. measurement..............4-3 Air flow measurement.................... 4-4Type K/J thermometer .................... 4-5 Data Hold......................4-6 Data Record ( Max., Min. reading ).............. 4-7 LCD Backlight ON/OFF..................
  • Page 3: Features

    1. FEATURES * One meter can accept one probes : anemometer probe * Air velocity : m/s, Ft/min, Km/h, Knot, Mile/h, * Air flow ( CFM, CMM ) measurement. * Air temperature ( ℃, ℉ ) * Air Temp. used thermistor sensor, fast response time. * Fast humidity measuring response time.
  • Page 4: Specifications

    * Applications : Environmental testing, HVAC, Air conveyors, Flow hoods, Clean rooms, Air velocity, Air balancing, Fans/motors/blowers, Furnace velocity, Refrigerated case, Paint spray booths . measurements 2. SPECIFICATIONS 2-1 General Specifications Circuit Custom one-chip of microprocessor LSI circuit. Display LCD size : 52 mm x 38 mm LCD with green backlight ( ON/OFF ).
  • Page 5 Datalogger Auto 1 second to 3600 seconds Sampling Time Sampling time can set to 1 second, Setting range but memory data may loss. Manual Push the data logger button once will save data one time. Set the sampling time to 0 second.
  • Page 6 Sampling Time Approx. 1 second. of Display Data Output RS 232/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug. * Connect the optional USB cable USB-01 will get the USB plug. Operating 0 to 50 ℃. Temperature Operating Less than 85% R.H.
  • Page 7 Optional * SD Card ( 4 G ) Accessories * Type K thermocouple probes, refer to page 27. * AC to DC 9V adapter. * USB cable, USB-01. * RS232 cable, UPCB-02. * Data Acquisition software, SW-U801-WIN. * Excel Data Acquisition software, SW-E802 2-2 Electrical Specifications (23±5 ℃...
  • Page 8 Air flow Measurement Range Resolution CMM ( m^3/min. ) 0 to 54,000 CMM 0.001 to 1 CMM CFM ( ft^3/min. ) 0 to 1,907,000 CFM 0.001 to 100 CFM Measurement Area CMM ( m^3/min. ) 0.001 to 30.000 m^2 CFM ( ft^3/min. ) 0.01 to 322.93 ft^2 Type K/J thermometer Sensor...
  • Page 9: Front Panel Description

    3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-12 RS-232 Output Terminal 3-2 Power Button ( Backlight Button ) 3-13 Reset Button 3-3 Hold Button 3-14 DC 9V Power Adapter Input Socket 3-4 REC Button 3-15 Battery Compartment/Cover 3-5 UNIT Button ( ▲ Button ) 3-16 Battery Cover Screws 3-6 SET Button ( Time Button ) 3-17 Stand...
  • Page 10: Measuring Procedure

    4. MEASURING PROCEDURE 4-1 Function selection 1) Power on the meter by pressing the " Power button " ( 3-2, Fig. 1 ) > 1.5 seconds continuously. * After already power on the meter, pressing the " Power button " > 1.5 seconds continuously will turn off the meter.
  • Page 11: Air Velocity/Temp. Measurement

    4-2 Air velocity/Temp. measurement a. Function select to " Air velocity/Temp. " measurement. b.. Plug the " Probe Plug " ( 3-19, Fig. 1 ) into the " Probe Input Socket " ( 3-9, Fig. 1 ). Power on the meter by pressing the " Power Button " ( 3-2, Fig.
  • Page 12: Air Flow Measurement

    4-3 Air flow measurement. a. Function select to " Air flow " , refer to page 8. AirF/USA : Air flow in CFM unit AirF/Euro : Air flow in CMM unit Remark : a. How to select the CFM air flow or CMM air flow, details please reefer to Chapter 7-9, page 22.
  • Page 13: Data Hold

    4-5 Data Hold During the measurement, press the " Hold Button " ( 3-3, Fig. 1 ) once will hold the measured value & the LCD will display a " HOLD " symbol. Press the " Hold Button " once again will release the data hold function.
  • Page 14: Datalogger

    5. DATALOGGER 5-1 Preparation before execute datalogger function a. Insert the SD card Prepare a " SD memory card " ( 1 G to 16 G, optional ), * It recommend use memory card 4 GB. ≦ insert the SD card into the " SD card socket " ( 3-11, Fig. 1). The front panel of the SD card should face against the the down case.
  • Page 15 then " REC " symbol will flashing per sampling time, at the same time the measuring data along the time information will be saved into the memory circuit. Remark : How to set the sampling time, refer to Chapter 7-2, page 19.
  • Page 16: Manual Datalogger ( Set Sampling Time = 0 Second )

    5-3 Manual Datalogger ( Set sampling time = 0 second ) a. Set sampling time is to 0 second Press the " LOG Button ( 3-8, Fig. 1 ) > 1.5 second , the lower LCD will show the " Position no. " ( or show the Position no.
  • Page 17: Sd Card Data Structure

    5-5 SD Card Data structure 1) When the SD card is used into the meter, the SD card When the first time, the SD card is used into the meter, the SD card will generate a folder : AHB01 2) If the first time to execute the Datalogger, under the route AM01\, will generate a new file name AM01001.XLS.
  • Page 18: Saving Data From The Sd Card To The Computer

    6. Saving data from the SD card to the computer ( EXCEL software ) 1) After execute the Data Logger function, take away the SD card out from the " SD card socket " ( 3-11, Fig. 1 ). 2) Plug in the SD card into the Computer's SD card slot ( if your computer build in this installation ) or insert the SD card into the "...
  • Page 19 EXCEL graphic screen ( for example )
  • Page 20: Advanced Setting

    7. ADVANCED SETTING Under do not execute the Datalogger function, press the " SET Button " ( 3-6, Fig. 1 ) continuously at least two seconds will enter the " Advanced Setting " mode. then press the " SET Button " (3-6, Fig. 1 ) once a while in sequence to select the ten main function, the lower display will show : dAtE..
  • Page 21: Auto Power Off Management

    value is Year then next to adjust Month, Date, Hour, Minute, Second value ). Remark : The adjusted value will be flashed. 2) After set all the time value ( Year, Month, Date, Hour, Minute, Second ), press the " ENETER Button " ( 3-8, Fig.
  • Page 22: Set Beep Sound On/Off

    7-4 Set beeper sound ON/OFF When the lower display show " bEEP " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to select the upper value to " yES " or "...
  • Page 23: Sd Memory Card Format

    7-6 SD memory card Format When the lower display show " Sd F " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to select the upper value to " yES " or "...
  • Page 24: Select The Thermometer Type To Type K Or Type J

    7-8 Select the Thermometer to Type K or Type J When the lower display show " tYPE " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to select the Display unit to " K " or " J " K - Type K thermometer j - Type J thermometer 2) After Display unit is selected to "...
  • Page 25: Set Air Flow Area Dimension

    7-10 Set the area size of Air flow measurement When the lower display show " ArEA " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to select the lower Display text to " ArEA/Euro " or "...
  • Page 26: Power Supply From Dc Adapter

    8. POWER SUPPLY from DC ADAPTER The meter also can supply the power supply from the DC 9V Power Adapter ( optional ). Insert the plug of Power Adapter into " DC 9V Power Adapter Input Socket " ( 3-14, Fig. 1 ). The meter will permanent power ON when use the DC ADAPTER power supply ( The power Button function is disable ).
  • Page 27: System Reset

    10. SYSTEM RESET If the meter happen the troubles such as : CPU system is hold ( for example, the key button can not be operated... ). Then make the system RESET will fix the problem. The system RESET procedures will be either following method : During the power on, use a pin to press the "...
  • Page 28 The 16 digits data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status : End Word D1 & D8 Display reading, D1 = LSD, D8 = MSD For example : If the display reading is 1234, then D8 to...
  • Page 29: Optional Type K Temp. Probe

    12. Optional Type K Temp. probe (Type K) TP-01 * Max. short-tern operating Temperature: 300 ℃ (572 ℉). * It is an ultra fast response naked-bead thermocouple suitable for many general purpose application. Thermocouple * Measure Range: -50 ℃ to 900 ℃, Probe -58 ℉...

Table of Contents