SD card real time Data Recorder + Type K/J thermometer, Air flow ANEMOMETER Model : AM-4233SD Your purchase of this ANEMOMETER & THERMOMETER with SD CARD DATA LOGGER marks a step forward for you into the field of precision measurement.
TABLE OF CONTENTS 1. FEATURES......................2. SPECIFICATIONS.................... 3. FRONT PANEL DESCRIPTION..............4. MEASURING PROCEDURE................4-1 Function selection ....................4-2 Air velocity/Temp. measurement..............4-3 Air flow measurement.................... 4-4Type K/J thermometer .................... 4-5 Data Hold......................4-6 Data Record ( Max., Min. reading ).............. 4-7 LCD Backlight ON/OFF..................
1. FEATURES * One meter can accept one probes : anemometer probe * Air velocity : m/s, Ft/min, Km/h, Knot, Mile/h, * Air flow ( CFM, CMM ) measurement. * Air temperature ( ℃, ℉ ) * Air Temp. used thermistor sensor, fast response time. * Fast humidity measuring response time.
* Applications : Environmental testing, HVAC, Air conveyors, Flow hoods, Clean rooms, Air velocity, Air balancing, Fans/motors/blowers, Furnace velocity, Refrigerated case, Paint spray booths . measurements 2. SPECIFICATIONS 2-1 General Specifications Circuit Custom one-chip of microprocessor LSI circuit. Display LCD size : 52 mm x 38 mm LCD with green backlight ( ON/OFF ).
Page 5
Datalogger Auto 1 second to 3600 seconds Sampling Time Sampling time can set to 1 second, Setting range but memory data may loss. Manual Push the data logger button once will save data one time. Set the sampling time to 0 second.
Page 6
Sampling Time Approx. 1 second. of Display Data Output RS 232/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug. * Connect the optional USB cable USB-01 will get the USB plug. Operating 0 to 50 ℃. Temperature Operating Less than 85% R.H.
Page 7
Optional * SD Card ( 4 G ) Accessories * Type K thermocouple probes, refer to page 27. * AC to DC 9V adapter. * USB cable, USB-01. * RS232 cable, UPCB-02. * Data Acquisition software, SW-U801-WIN. * Excel Data Acquisition software, SW-E802 2-2 Electrical Specifications (23±5 ℃...
Page 8
Air flow Measurement Range Resolution CMM ( m^3/min. ) 0 to 54,000 CMM 0.001 to 1 CMM CFM ( ft^3/min. ) 0 to 1,907,000 CFM 0.001 to 100 CFM Measurement Area CMM ( m^3/min. ) 0.001 to 30.000 m^2 CFM ( ft^3/min. ) 0.01 to 322.93 ft^2 Type K/J thermometer Sensor...
4. MEASURING PROCEDURE 4-1 Function selection 1) Power on the meter by pressing the " Power button " ( 3-2, Fig. 1 ) > 1.5 seconds continuously. * After already power on the meter, pressing the " Power button " > 1.5 seconds continuously will turn off the meter.
4-2 Air velocity/Temp. measurement a. Function select to " Air velocity/Temp. " measurement. b.. Plug the " Probe Plug " ( 3-19, Fig. 1 ) into the " Probe Input Socket " ( 3-9, Fig. 1 ). Power on the meter by pressing the " Power Button " ( 3-2, Fig.
4-3 Air flow measurement. a. Function select to " Air flow " , refer to page 8. AirF/USA : Air flow in CFM unit AirF/Euro : Air flow in CMM unit Remark : a. How to select the CFM air flow or CMM air flow, details please reefer to Chapter 7-9, page 22.
4-5 Data Hold During the measurement, press the " Hold Button " ( 3-3, Fig. 1 ) once will hold the measured value & the LCD will display a " HOLD " symbol. Press the " Hold Button " once again will release the data hold function.
5. DATALOGGER 5-1 Preparation before execute datalogger function a. Insert the SD card Prepare a " SD memory card " ( 1 G to 16 G, optional ), * It recommend use memory card 4 GB. ≦ insert the SD card into the " SD card socket " ( 3-11, Fig. 1). The front panel of the SD card should face against the the down case.
Page 15
then " REC " symbol will flashing per sampling time, at the same time the measuring data along the time information will be saved into the memory circuit. Remark : How to set the sampling time, refer to Chapter 7-2, page 19.
5-3 Manual Datalogger ( Set sampling time = 0 second ) a. Set sampling time is to 0 second Press the " LOG Button ( 3-8, Fig. 1 ) > 1.5 second , the lower LCD will show the " Position no. " ( or show the Position no.
5-5 SD Card Data structure 1) When the SD card is used into the meter, the SD card When the first time, the SD card is used into the meter, the SD card will generate a folder : AHB01 2) If the first time to execute the Datalogger, under the route AM01\, will generate a new file name AM01001.XLS.
6. Saving data from the SD card to the computer ( EXCEL software ) 1) After execute the Data Logger function, take away the SD card out from the " SD card socket " ( 3-11, Fig. 1 ). 2) Plug in the SD card into the Computer's SD card slot ( if your computer build in this installation ) or insert the SD card into the "...
7. ADVANCED SETTING Under do not execute the Datalogger function, press the " SET Button " ( 3-6, Fig. 1 ) continuously at least two seconds will enter the " Advanced Setting " mode. then press the " SET Button " (3-6, Fig. 1 ) once a while in sequence to select the ten main function, the lower display will show : dAtE..
value is Year then next to adjust Month, Date, Hour, Minute, Second value ). Remark : The adjusted value will be flashed. 2) After set all the time value ( Year, Month, Date, Hour, Minute, Second ), press the " ENETER Button " ( 3-8, Fig.
7-4 Set beeper sound ON/OFF When the lower display show " bEEP " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to select the upper value to " yES " or "...
7-6 SD memory card Format When the lower display show " Sd F " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to select the upper value to " yES " or "...
7-8 Select the Thermometer to Type K or Type J When the lower display show " tYPE " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to select the Display unit to " K " or " J " K - Type K thermometer j - Type J thermometer 2) After Display unit is selected to "...
7-10 Set the area size of Air flow measurement When the lower display show " ArEA " 1) Use the " ▲ Button " ( 3-5, Fig. 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to select the lower Display text to " ArEA/Euro " or "...
8. POWER SUPPLY from DC ADAPTER The meter also can supply the power supply from the DC 9V Power Adapter ( optional ). Insert the plug of Power Adapter into " DC 9V Power Adapter Input Socket " ( 3-14, Fig. 1 ). The meter will permanent power ON when use the DC ADAPTER power supply ( The power Button function is disable ).
10. SYSTEM RESET If the meter happen the troubles such as : CPU system is hold ( for example, the key button can not be operated... ). Then make the system RESET will fix the problem. The system RESET procedures will be either following method : During the power on, use a pin to press the "...
Page 28
The 16 digits data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status : End Word D1 & D8 Display reading, D1 = LSD, D8 = MSD For example : If the display reading is 1234, then D8 to...
12. Optional Type K Temp. probe (Type K) TP-01 * Max. short-tern operating Temperature: 300 ℃ (572 ℉). * It is an ultra fast response naked-bead thermocouple suitable for many general purpose application. Thermocouple * Measure Range: -50 ℃ to 900 ℃, Probe -58 ℉...