WaterLogic WL250 Troubleshooting Manual page 2

Advertisement

1. Dispensing Won't Stop when Not Holding the Dispensing Button 
 
 
Possible Reason 
Too much water pressure.  
Recommend 40‐60 psi for the 
WL250 Water Treatment 
System to operate properly. 
Bad Display PCB  
Debris in the Solenoid  
Dispensing Button Stuck 
 
 
WL250 Manual 
The correct input water pressure is critical to the performance of 
the unit to allow solenoids to open. 
 
Check water pressure at the inlet bulkhead with a water pressure 
gauge. 
 
Additional method of verification is to turn off water to unit and 
press the dispense button.  Does the solenoid open without water 
pressure to the unit?  Listen for solenoid to activate, not button 
"click". 
 
Adjust water pressure to 40‐60 psi. 
Replace Front PCB 
Hot and Cold – P/N EN‐6085 WLCP PN 12‐8103 
Cold Only – P/N EN‐6086 WLCP PN 12‐8615 
Inspect Solenoid for debris and clean out as needed. 
Dirt or Foreign material is filling the gap around the push‐buttons. 
Inspect the push buttons and clean surrounding area.  Inspect 
faucet assembly inside the unit and clean as necessary. 
 
                                                      Page 56 ‐ Revision: 12‐12‐2018 
Solution 