Detailed Descaling and Sanitizing Procedure
Use Ice Machine Cleaner/Descaler part number
000000084.
Use Ice Machine Sanitizer part number 9405653.
Remove front and top covers and set the toggle
Step 1
switch to the OFF position.
Remove all ice from the bin.
Step 2
Turn off the ice making water supply and drain
Step 3
water from evaporator and reservoir.
Remove the top cover from water reservoir.
Step 4
Follow the chart and premix cleaner and water.
Step 5
Amount of Water
4 Liters (1 gallon)
Fill the evaporator and reservoir with descaling
Step 6
solution.
Prop Float Up to Prevent Low Water Level Shutdown
26
Amount of Cleaner/Descaler
Part Number 000000084

Important
90 milliliter (3 oz)
Part Number STH105 5/20