INSTALLATION REQUIREMENTS AND
This chapter describes the following:
Site guidelines that must be met before installing a DLM6C-AA into a
rack or cabinet
DLM6C-AA configuration guidelines
Operating specifications for the DLM6C-AA enclosure and power
supply modules
Only qualified personnel should install or service this unit.
2.1

SITE GUIDELINES

The following guidelines must be followed when a site is selected for the
DLM6C-AA. If the guidelines are not followed, unsatisfactory network
performance may result.
To allow proper cooling within the rack, there must be
3 inches of clearance above the unit and 2 inches of clearance on either
side of the unit.
If the DLM6C-AA is to be placed on a shelving unit, the shelf must be
able to support 75 pounds of static weight.
If the DLM6C-AA is to be rack mounted, care must be taken to ensure
that the rack used will support the unit and that the rack remains stable
with the DLM6C-AA installed.
The HA205-AA ac power supply requires a standard three-pronged
power receptacle that is located within 6 feet of the site.
The temperature of the location must be maintained between 5° and
40°C (41° to 104°F). Temperature changes of greater than 10°C (18°F)
per hour must not occur.
DLM6C-AA Overview and Setup Guide
CHAPTER 2
SPECIFICATIONS
2-1