5.4.2 Deep Cleaning (Boiling Out/Cold Clean) the Frypot – Minimally Monthly
During normal usage of your fryer, a deposit of carbonized oil will gradually form on the inside of the
frypot. This film should be periodically removed by following the Clean (boil-out) procedure. Refer to
sections 2.1.11 and 2.1.12 of the FilterQuick
details on setting up the controller for clean (boil-out) operation.
Never operate the appliance with an empty frypot. The frypot must be filled to the fill line with
water or cooking oil before energizing the elements. Failure to do so will result in irreparable
damage to the elements and may cause a fire.
Allow oil to cool to 100ºF (38ºC) or lower before draining to an appropriate container for disposal.
Never leave the fryer unattended during this process.
ON/OFF switch to the OFF position immediately.
Ensure that the frypot is completely free of water before filling with oil. When the oil is heated to
cooking temperature, water in the frypot will cause splattering.
To prevent injury, ensure adjacent vats that contain oil are OFF and covered prior to performing
a Hot Clean (Boil Out) or Cold Clean (Cold Soak).
5.4.3 Pre-filter Maintenance - Monthly
The pre-filter requires regular maintenance. Every 30 days, or more
frequently if the flow of oil slows, remove the cap and clean the
attached screen.
Wear protective gloves when removing the pre-filter. The
filter may be hot and cause severe burns.
1. Wearing protective gloves use the supplied wrench to remove
the cap from the pre-filter (Figure 2).
2. Use a small brush to clear debris from the attached screen (Figure 3).
3. Clean under a water tap and thoroughly dry.
4. Return the cap to the pre-filter housing and tighten with the attached wrench, ensuring the pre-
filter is tight. If the cap is not tight, air will leak around the pre-filter and slow the return.
DO NOT remove the pre-filter cap when a filter cycle is under way.
DO NOT operate the filter system with the cap removed. Wear protective gloves when handling
the cap. The metal and the exposed oil are hot.