Marker Position Switch; Tri-Fold Breakaway Marker; Shear Bolts - MASSEY FERGUSON 9831 Service Manual

Planter
Table of Contents

Advertisement

Marker Position Switch

FIG. 22: As the planter frame hitch cylinder extends, the
marker position switch (1) opens, disconnecting the
marker raise/lower circuit. When the frame is unfolded
and the hitch is level with the frame, the position switch is
closed, permitting normal marker operation.

Tri-fold Breakaway Marker

The tri-fold breakaway marker includes a notched disc.
When the breakaway marker makes contact with a solid
obstruction, the shear bolt can give with some resistance
and break.

Shear Bolts

FIG. 23: The markers are protected with a 3/8 x 3 Inch
Grade 5 shear bolt (1) and lock nut.
Tighten the lock nut to 42 Nm (23 lbf ft).
IMPORTANT: Replace only with the correct size and
grade.
NOTE: Use a bolt with a shoulder, and not a full threaded
bolt.
4283532M1
Field Operations and Adjustments
1
FIG. 22
1
FIG. 23
L809332
LB04786
01-29

Advertisement

Table of Contents
loading

Table of Contents