Pentair STA-RITE J Series Installation And Operation Manual
Pentair STA-RITE J Series Installation And Operation Manual

Pentair STA-RITE J Series Installation And Operation Manual

60 cycle centrifigual pump
Hide thumbs Also See for STA-RITE J Series:
Table of Contents

Advertisement

Available languages

Available languages

60 CYCLE CENTRIFIGUAL PUMP
J SERIES
JB SERIES
ENGLISH: 1-16
ESPANOL: 17-32
INSTALLATION AND
OPERATION MANUAL
pentair.com
S873-OIM (09-09-19)
STA-RITE
*
1

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Pentair STA-RITE J Series

  • Page 1 STA-RITE 60 CYCLE CENTRIFIGUAL PUMP J SERIES JB SERIES  ENGLISH: 1-16 ESPANOL: 17-32  INSTALLATION AND OPERATION MANUAL pentair.com S873-OIM (09-09-19)
  • Page 2: Table Of Contents

    TABLE OF CONTENTS: SECTION ........................................PAGE Safety ........................................3 Installation ......................................4-6 Maintenance ......................................7-8 Specifications ..................................... 9-14 Troubleshooting ......................................15 Warranty ........................................16 S873-OIM (09-09-19)
  • Page 3: Safety

    SAFETY IMPORTANT SAFETY INSTRUCTIONS GENERAL SAFETY SAVE THESE INSTRUCTIONS: For optimal performance and Risk of explosion. The pump body may explode if operation, read these instructions carefully before installing used to boost pressure above the pressures noted on Page 3. your new pump.
  • Page 4: Installation

    INSTALLATION Short length of straight pipe after reducer Tee and Priming Plug Important: Priming All connections must Plug be air tight Discharge Street Elbow to service Support suction pipe Eccentric Union as required Reducer Gate Valve Solid, level base Vent Support discharge Straight run, short as Plug...
  • Page 5 INSTALLATION PIPING - GENERAL DISCHARGE PIPING Support both suction and discharge piping independently at Increase pipe size from pump tapping as show in Table I. a point near the pump to avoid putting a strain on the pump Figure 1 (Page 4) depicts a recommended run of pipe and fittings housing.
  • Page 6 INSTALLATION WIRING CONNECTION DIAGRAM FOR DUAL VOLTAGE, Ground motor before connecting to electrical power SINGLE-PHASE MOTORS supply. Failure to ground motor can cause severe or fatal Your dual-voltage motor’s terminal board (under the motor end electrical shock hazard. cover) will match one of the diagrams below. Follow that diagram if necessary to convert motor to 115 Volt power.
  • Page 7: Maintenance

    MAINTENANCE PUMP SERVICE INSTALLATION OF FLOATING SEAT This centrifugal pump requires little or no service other than (SEE FIGURE 5-C SHOWN BELOW) reasonable care and periodic cleaning. Follow the procedure Clean polished surface of floating seat with clean cloth. outlined below for shaft seal replacement. Turn seal plate over so seal cavity is up, clean cavity thoroughly.
  • Page 8 ORDERING REPLACEMENT PARTS Locate the Pentair Sta-Rite* nameplate on pump. This plate is normally on the pump case or bracket (seal plate). To ensure receipt of correct parts, provide all nameplate data when ordering. Catalog number is most important to reference.
  • Page 9: Specifications

    SPECIFICATIONS 8,8A 801 0394 REPAIR PARTS LIST – “J” SERIES - HIGH HEAD MOTOR AND HORSEPOWER Part JHB-61HL JHC-61HL JHD-62HL JHE-63HL JHF-51HL JHG-52HL JHHG-53HL Description Used – JHC3-61H JHD3-62H JHE3-63H JHF3-51H JHG3-52H JHHG3-53H 1/3 HP 1/2 HP 3/4 HP 1 HP 1-1/2 HP 2 HP 2-1/2 HP...
  • Page 10 SPECIFICATIONS 2409 0496 SPC This drawing is for use with Models using a capscrew con guration. REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD MOTOR AND HORSEPOWER Part JMB-56L JMC-56L JMD-57L JME-58L Description Used – JMC3-56 JMD3-57 JME3-58 1/3 HP 1/2 HP 3/4 HP 1 HP...
  • Page 11 SPECIFICATIONS 2410 0496 SPC REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD This drawing is for use with Models using a stud con guration. MOTOR AND HORSEPOWER Part JMF-40L JMG-41L Description Used JMF3-40 JMG3-41 1-1/2 HP 2 HP Motor, 115/230V, 1 Phase J218-601PKG J218-883APKG Motor, 230/460V, 3 Phase...
  • Page 12 SPECIFICATIONS 2407 0217 REPAIR PARTS LIST – “JB” SERIES - HIGH HEAD MOTOR AND HORSEPOWER JBHB-61S JBHC-61S JBHD-62S JBHE-63S JBHF-51S JBHG-52S JBHHG-53S Part Description Used – JBHC3-61S JBHD3-62S JBHE3-63S JBHF3-51S JBHG3-52S JBHHG3-53S 1/3 HP 1/2 HP 3/4 HP 1 HP 1-1/2 HP 2-1/2 HP J218-...
  • Page 13 SPECIFICATIONS 2409 0496 SPC REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD This drawing is for use with MOTOR AND HORSEPOWER Models using a capscrew con guration. Part JBMB-56S JBMC-56S JBMD-57S JBME-58S Description Used – JBMC3-56S JBMD3-57S JBME3-58S 1/3 HP 1/2 HP 3/4 HP 1 HP...
  • Page 14 SPECIFICATIONS 2410 0496 SPC This drawing is for use with REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD Models using a stud con guration. MOTOR AND HORSEPOWER Part JBMF-40S JBMG-41S JBMMG-59S Description Used JBMF3-40S JBMG3-41S JBMMG3-59S 1-1/2 HP 2 HP 2-1/2 HP Motor, 115/230V, 1 Phase J218-601PKG...
  • Page 15: Troubleshooting

    TROUBLESHOOTING Probable cause Symptoms Electrical Mechanical System Pump runs, but no water delivered Not enough water delivered Not enough pressure Excessive vibration Abnormal Noise Pump stops Overheating Cause Corrective Action Electrical Check phase-to-phase on line side of starter contactor. A. No voltage in power system. Check circuit breaker or fuses Check phase voltage on line side of starter contactor.
  • Page 16: Warranty

    *For a detailed list of where Pentair trademarks are registered, please visit www.pentair.com/en/registrations.html. Pentair trademarks and logos are owned by Pentair PLC. or its affiliates. Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
  • Page 17 STA-RITE BOMBA CENTRÍFUGA DE 60 CICLOS J SERIES JB SERIES  MANUAL DE INSTALACIÓN Y OPERACIÓN pentair.com S873-OIM-SP (09-09-19)
  • Page 18 ÍNDICE: SECCIÓN......................................PÁGINA Seguridad ........................................19 Instalación ......................................20-22 Mantenimiento ....................................23-24 Especificaciones ....................................25-30 Solución de problemas .....................................31 Garantía........................................32 S873-OIM-SP (09-09-19)
  • Page 19: Seguridad

    SEGURIDAD INSTRUCCIONES IMPORTANTES DE SEGURIDAD   Se debe incorporar un interruptor de desconexión total de alimentación al cableado fijo. GUARDE ESTAS INSTRUCCIONES: Para alcanzar un rendimiento y   Instale, conecte a tierra, cablee y mantenga su bomba de funcionamiento óptimos, lea estas instrucciones detenidamente acuerdo con todos los códigos y ordenanzas nacionales y locales antes de instalar su bomba nueva.
  • Page 20: Instalación

    INSTALACIÓN Tubería recta corta después del reductor Conexión en T y tapón de cebado. Importante: Tapón de ¡Todas las conexiones cebado deben ser herméticas! Codo Extremo de macho-hembra descarga al servicio Reductor Apoye la tubería de succión Unión según las especi caciones. excéntrico Válvula de paso...
  • Page 21 INSTALACIÓN TUBERÍA: CONSIDERACIONES GENERALES TUBERÍA DE DESCARGA Para evitar presionar la carcasa de la bomba, apoye las tuberías de Aumente el diámetro de la tubería desde la toma de la bomba, como se succión y descarga de forma independiente en un punto cerca de la muestra en la Tabla I.
  • Page 22 INSTALACIÓN DIAGRAMA DE CONEXIÓN PARA MOTORES MONOFÁSICOS DE DOBLE CABLEADO TENSIÓN Conecte a tierra el motor antes de conectarlo a la fuente de El panel de terminales del motor de doble tensión (debajo de la tapa del alimentación. Si no se conecta a tierra el motor, se puede producir un extremo del motor) debe coincidir con uno de los diagramas a continuación.
  • Page 23: Mantenimiento

    MANTENIMIENTO TAREAS DE MANTENIMIENTO EN LA BOMBA INSTALACIÓN DEL ASIENTO FLOTANTE Esta bomba centrífuga requiere poco o ningún mantenimiento, aparte (CONSULTE LA FIGURA 5-C QUE SE MUESTRA A CONTINUACIÓN). de un cuidado razonable y limpieza periódica. Para reemplazar el sello Limpie la superficie pulida del asiento flotante con un paño limpio. del eje, siga el procedimiento descrito a continuación.
  • Page 24 MANTENIMIENTO PEDIDO DE PIEZAS DE REPUESTO Ubique la placa de identificación en la bomba Pentair Sta-Rite*. Por lo general, esta placa se encuentra en la carcasa o soporte de la bomba (placa de estanqueidad). A fin de garantizar que reciba las piezas correctas, proporcione toda la información que figura en la placa de identificación cuando realice el pedido.
  • Page 25: Especificaciones

    ESPECIFICACIONES 8,8A LISTA DE PIEZAS DE REPUESTO - J SERIES - ALTA PRESIÓN 801 0394 MOTOR Y POTENCIA Núm. de Cant. JHF-51HL JHHG-53HL Descripción de la pieza JHC-61HL JHD-62HL JHE-63HL JHG-52HL referencia empleada JHB-61HL – 1/3 Hp JHF3-51H JHHG3-53H JHC3-61H 1/2 Hp JHD3-62H 3/4 Hp JHE3-63H 1 Hp JHG3-52H 2 Hp 1-1/2 Hp...
  • Page 26 ESPECIFICACIONES 2409 0496 SPC This drawing is for use with LISTA DE PIEZAS DE REPUESTO - J SERIES - PRESIÓN MEDIA Models using a capscrew con guration. MOTOR Y POTENCIA Núm. de Cant. Descripción de la pieza referencia empleada JMC-56L JMD-57L JME-58L JMB-56L –...
  • Page 27 ESPECIFICACIONES 2410 0496 SPC LISTA DE PIEZAS DE REPUESTO - J SERIES - PRESIÓN MEDIA This drawing is for use with Models using a stud con guration. MOTOR Y POTENCIA Núm. Cant. Descripción de la pieza JMF-40L JMG-41L empleada referencia JMF3-40 1-1/2 Hp JMG3-41 2 Hp Motor monofásico de 115/230 V J218-601PKG...
  • Page 28 ESPECIFICACIONES LISTA DE PIEZAS DE REPUESTO - JB SERIES - ALTA PRESIÓN 2407 0217 MOTOR Y POTENCIA Núm. de Cant. JBHB-61S JBHC-61S JBHD-62S JBHE-63S JBHF-51S JBHG-52S JBHHG-53S Descripción de la pieza referencia empleada – JBHC3-61S JBHD3-62S JBHE3-63S JBHF3-51S JBHG3-52S JBHHG3-53S 1/3 Hp 1/2 Hp 3/4 Hp 1 Hp...
  • Page 29 ESPECIFICACIONES 2409 0496 SPC LISTA DE PIEZAS DE REPUESTO - J SERIES - PRESIÓN MEDIA This drawing is for use with MOTOR Y POTENCIA Models using a capscrew con guration. Núm. de Cant. JBMB-56S JBMC-56S JBMD-57S Descripción de la pieza JBME-58S referencia empleada –...
  • Page 30 ESPECIFICACIONES 2410 0496 SPC This drawing is for use with LISTA DE PIEZAS DE REPUESTO - J SERIES - PRESIÓN MEDIA Models using a stud con guration. MOTOR Y POTENCIA Núm. de JBMF-40S JBMG-41S JBMMG-59S Descripción de la pieza Cant. empleada referencia JBMF3-40S JBMG3-41S...
  • Page 31: Solución De Problemas

    SOLUCIÓN DE PROBLEMAS Causas probables Síntomas Eléctrica Mecánica Del sistema La bomba funciona, pero no bombea agua. La bomba no bombea el agua suficiente. El agua no tiene la presión suficiente. La bomba tiene una vibración excesiva. La bomba produce ruidos anormales. La bomba se detiene.
  • Page 32: Garantía

    Para obtener una lista detallada de los lugares en que las marcas comerciales de Pentair se encuentran registradas, visite www.pentair.com/en/registrations. html. Las marcas comerciales y los logotipos de Pentair son propiedad de Pentair PLC. o de sus filiales. Las marcas comerciales y los logotipos registrados y no registrados de cualquier tercero son propiedad de sus respectivos propietarios.

Table of Contents