INSTALLATION AND OPERATING INSTRUCTIONS
HP
MEDIUM HEAD MODELS
1/3
JBMB-56S
1/2
JBMC-56S
3/4
JBMD-57S
1
JBME-58S
1-1/2
JBMF-40S
2
JBMG-41S
2-1/2 JBMMG-59S JBMMG3-59S
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM
PH: 888-782-7483
© 2013 Pentair Ltd. All Rights Reserved.
REPAIR PARTS LIST
JMB-56L
JBMC3-56S
JMC-56L JMC3-56 JBHC-61S
JBMD3-57S
JMD-57L JMD3-57 JBHD-62S
JBME3-58S
JME-58L JME3-58 JBHE-63S
JBMF3-40S
JMF-40L JMF3-40 JBHF-51S
JBMG3-41S
JMG-41L JMG3-41 JBHG-52S
60 Cycle "J" and "JB" Series
671 0294
MODELS
HIGH HEAD MODELS
JBHB-61S
JBHC3-61S
JBHD3-62S
JBHE3-63S
JBHF3-51S
JBHG3-52S
JBHHG-53S JBHHG3-53S JHHG-53HL JHHG3-53H
OWNER'S MANUAL
Centrifugal Pump
JHB-61HL
JHC-61HL
JHC3-61H
JHD-62HL
JHD3-62H
JHE-63HL
JHE3-63H
JHF-51HL
JHF3-51H
JHG-52HL
JHG3-52H
S873 (REV 01/14/13)

Advertisement

loading
Need help?

Need help?

Do you have a question about the Sta-Rite J Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pentair Sta-Rite J Series

  • Page 1 JMF-40L JMF3-40 JBHF-51S JBHF3-51S JHF-51HL JHF3-51H JBMG-41S JBMG3-41S JMG-41L JMG3-41 JBHG-52S JBHG3-52S JHG-52HL JHG3-52H 2-1/2 JBMMG-59S JBMMG3-59S – – JBHHG-53S JBHHG3-53S JHHG-53HL JHHG3-53H 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM PH: 888-782-7483 S873 (REV 01/14/13) © 2013 Pentair Ltd. All Rights Reserved.
  • Page 2 Short length of straight pipe after reducer Tee and Priming Plug Important: Priming All connections must Plug be air tight Discharge Street Elbow to service Support suction pipe Eccentric Union as required Reducer Gate Valve Solid, level base Vent Support discharge Straight run, short as Plug pipe as required...
  • Page 3 DISCHARGE PIPING California Proposition 65 Warning This product and related accessories Increase pipe size from pump tapping as show in Table I. contain chemicals known to the State of California to Figure 1 (Page 2) depicts a recommended run of pipe and cause cancer, birth defects or other reproductive harm.
  • Page 4 ELECTRICAL WIRING Connection diagram for dual voltage, single-phase motors. Your dual-voltage motor’s terminal board (under the Ground motor before connecting to electrical power motor end cover) will match one of the diagrams below. Follow that diagram if necessary to convert motor to 115 Volt power. supply.
  • Page 5: Pump Service

    SERVICE PUMP SERVICE INSTALLATION OF FLOATING SEAT (Figure 5C) 1. Clean polished surface of floating seat with clean cloth. This centrifugal pump requires little or no service other than 2. Turn seal plate over so seal cavity is up, clean cavity thor- reasonable care and periodic cleaning.
  • Page 6 8,8A 801 0394...
  • Page 8 REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD 2409 0496 SPC This drawing is for use with MOTOR AND HORSEPOWER Models using a capscrew configuration. JMB-56L JMC-56L JMD-57L JME-58L Part – JMC3-56 JMD3-57 JME3-58 Description Used 1/3 HP 1/2 HP 3/4 HP 1 HP Motor, 115/230V, Single Phase...
  • Page 9 2410 0496 SPC REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD This drawing is for use with Models using a stud configuration. MOTOR AND HORSEPOWER JMF-40L JMG-41L Part JMF3-40 JMG3-41 Description Used 1-1/2 HP 2 HP Motor, 115/230V, 1 Phase J218-601PKG J218-883APKG Motor, 230/460V, 3 Phase...
  • Page 10 2407 0496...
  • Page 12 2409 0496 SPC This drawing is for use with Models using a capscrew configuration. REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD MOTOR AND HORSEPOWER JBMB-56S JBMC-56S JBMD-57S JBME-58S Part – JBMC3-56S JBMD3-57S JBME3-58S Description Used 1/3 HP 1/2 HP 3/4 HP 1 HP Motor, 115/230V, 1 Phase...
  • Page 13 2410 0496 SPC This drawing is for use with Models using a stud configuration. REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD MOTOR AND HORSEPOWER JBMF-40S JBMG-41S JBMMG-59S Part JBMF3-40S JBMG3-41S JBMMG3-59S Description Used 1-1/2 HP 2 HP 2-1/2 HP Motor, 115/230V, 1 Phase J218-601PKG J218-883APKG J218-628APKG Motor, 230/460V, 3 Phase...
  • Page 14 TROUBLE - CAUSES AND REMEDY TROUBLE AND CAUSE REMEDY FAILURE TO PUMP 1. Pump not properly primed. 1. Make sure pump casing and suction line are full of water. See priming instructions. REDUCED CAPACITY AND/OR HEAD 1. Air pockets or leaks in suction line. 1.
  • Page 15 Limited Warranty STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period whichever occurs first: Water Systems Products —...