Page 2
Short length of straight pipe after reducer Tee and Priming Plug Important: Priming All connections must Plug be air tight Discharge Street Elbow to service Support suction pipe Eccentric Union as required Reducer Gate Valve Solid, level base Vent Support discharge Straight run, short as Plug pipe as required...
Page 3
DISCHARGE PIPING California Proposition 65 Warning This product and related accessories Increase pipe size from pump tapping as show in Table I. contain chemicals known to the State of California to Figure 1 (Page 2) depicts a recommended run of pipe and cause cancer, birth defects or other reproductive harm.
Page 4
ELECTRICAL WIRING Connection diagram for dual voltage, single-phase motors. Your dual-voltage motor’s terminal board (under the Ground motor before connecting to electrical power motor end cover) will match one of the diagrams below. Follow that diagram if necessary to convert motor to 115 Volt power. supply.
SERVICE PUMP SERVICE INSTALLATION OF FLOATING SEAT (Figure 5C) 1. Clean polished surface of floating seat with clean cloth. This centrifugal pump requires little or no service other than 2. Turn seal plate over so seal cavity is up, clean cavity thor- reasonable care and periodic cleaning.
Page 8
REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD 2409 0496 SPC This drawing is for use with MOTOR AND HORSEPOWER Models using a capscrew configuration. JMB-56L JMC-56L JMD-57L JME-58L Part – JMC3-56 JMD3-57 JME3-58 Description Used 1/3 HP 1/2 HP 3/4 HP 1 HP Motor, 115/230V, Single Phase...
Page 9
2410 0496 SPC REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD This drawing is for use with Models using a stud configuration. MOTOR AND HORSEPOWER JMF-40L JMG-41L Part JMF3-40 JMG3-41 Description Used 1-1/2 HP 2 HP Motor, 115/230V, 1 Phase J218-601PKG J218-883APKG Motor, 230/460V, 3 Phase...
Page 12
2409 0496 SPC This drawing is for use with Models using a capscrew configuration. REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD MOTOR AND HORSEPOWER JBMB-56S JBMC-56S JBMD-57S JBME-58S Part – JBMC3-56S JBMD3-57S JBME3-58S Description Used 1/3 HP 1/2 HP 3/4 HP 1 HP Motor, 115/230V, 1 Phase...
Page 13
2410 0496 SPC This drawing is for use with Models using a stud configuration. REPAIR PARTS LIST – “J” SERIES - MEDIUM HEAD MOTOR AND HORSEPOWER JBMF-40S JBMG-41S JBMMG-59S Part JBMF3-40S JBMG3-41S JBMMG3-59S Description Used 1-1/2 HP 2 HP 2-1/2 HP Motor, 115/230V, 1 Phase J218-601PKG J218-883APKG J218-628APKG Motor, 230/460V, 3 Phase...
Page 14
TROUBLE - CAUSES AND REMEDY TROUBLE AND CAUSE REMEDY FAILURE TO PUMP 1. Pump not properly primed. 1. Make sure pump casing and suction line are full of water. See priming instructions. REDUCED CAPACITY AND/OR HEAD 1. Air pockets or leaks in suction line. 1.
Page 15
Limited Warranty STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period whichever occurs first: Water Systems Products —...
Need help?
Do you have a question about the Sta-Rite J Series and is the answer not in the manual?
Questions and answers