10
MENU
SETTINGS

Set Minimum Speed (RPM)

The minimum pump speed can be set from 1100 RPM
to 3450 RPM. The default setting is 1100 RPM.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Set Min
Speed".
5. Press Select to change the setting. The cursor will
appear in the first number column.
6. Press the Up or Down arrows to change the minimum
speed setting from 1100 to 3450 RPM.
7. Press Enter to save.To cancel, press Escape to exit
edit mode without saving.
8. Press Escape to exit.

Set Maximum Speed (RPM)

The maximum speed can be set from 1100 RPM to
3450 RPM (default is 3450). Use this setting to set the
maximum running speed of the pump.
When the Sparus
Pump with Constant Flow Technology
is set to Priming "Enabled", the pump will speed up to and
run at this speed to prime. A service professional must
set the Maximum Speed of the pump to not exceed the
maximum flow rate of the system on which it will operate.
The Maximum Flow rate setting should be set so the
system never operates at or above 25" of Hg vacuum.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Set Max
Speed".
5. Press Select to change. The cursor will appear in
the first number column (ones).
6. Press Up or Down arrows to change the maximum
speed setting from 1100 to 3450 RPM.
7. Press Enter. Press Escape to exit. To cancel, press
the Escape to exit without saving.

Password Protection

The default setting for password protection is disabled.
When this feature is enabled, the pump display will
prompt for the password before allowing access to the
control panel and buttons.
The entered password is any combination of four (4)
digits.
SPARUS
Pump with Constant Flow Technology Installation and User's Guide
Pump Menu: Settings
Pump Address
(1-16) Default: ADDRESS 1
Set Time
(hr:mm) Default: 12:00 AM
AM/PM
Set AM/PM
24 hr.
Temperature Unit
Fahrenheit - Default: F°
C° Celsius
Screen Contrast
(1-5) Default 3
English - Default: English
Language
Set Min Speed
(450 RPM - 1700 RPM) - Default: 450 RPM
Set Max Speed
(1900 RPM - 3450 RPM) - Default: 3450 RPM
PASSWORD
Disabled/Enabled - Default: Disabled
Password Time Out (1 min. - 6 hours) Default:10 minutes
Enter Password (xxxx) Default: 1234
Password protection can always be turned off by
pressing Start/Stop.
Password protection cannot be turned back on with
Start/Stop while running in manual mode.
Pressing Start/Stop when the pump is off will return
it back to the Running Cycles Mode and run at
the next scheduled run time. If the present time is
within the scheduled run time, the pump will run the
scheduled speed.
All functions including programming are disabled in
Password Protection Mode.
Screen will read "Enter Password" if any button other
than the Start/Stop button is pressed
Key icon displayed in the upper left side of the
screen when Password Protection is on.
Setting Password
1. Press Menu. Press Select to select "Settings".
2. Use the Up or Down arrow to scroll to "Password".
3. Press Select. The default setting is "Disabled".
4. Press Up or Down arrow to change the setting to
"Enabled" and press Enter to save.
5. Press the Down arrow. "Password Timeout" is
displayed.
6. The factory default time is 10 minutes. This means
the pump will go into Password Protection mode 10
minutes after the last control panel key is pressed.
7. Press Select to change time setting from 1 minute
to 6 hours and press Enter to save.
8. Press Down arrow and then press Select on "Enter
Password" to change the setting.
9. Press the Left or Right arrows to move cursor and
press Up or Down arrow to change password number
to desired setting.
10. Press Enter to save. To cancel any changes, press
Escape to exit without saving.
Entering Password
1. Press any button (besides the speed button) to
prompt the screen for a password.
2. To enter password, use the Left and Right arrows to
move the cursor and the Up and Down arrow button
to scroll through the digit then press Enter to confirm.

Alarm Log

1. Press Menu.
2. Press Select to select "Settings".
3. Use the Up or Down arrows to scroll to "Alarm Log".
Press Select.
4. Press Select again to view alarm history.
5. Use Up or Down arrows to scroll through alarm history.

Advertisement