6. DIAG. TEST OPERATION
6.3.9

Ribbon Type Selection

< 1
>
D I A G N O S T I C
< 2
>
P A R A M E T E R
Press the [PAUSE] key ten times.
R I
B
B O N
Select either ribbon type with
the [FEED] key or [RESTART]
key. (See NOTE 1 and 2.)
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables
a fast forward.
2. Non-transmissive (NON TRANS.) ribbon cannot be used so the ribbon type must be
set to transmissive (TRANS.) ribbon.
3. A changed ribbon type is stored in memory by pressing the [PAUSE] key.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
S E T
Press the [RESTART]
key. (See NOTE 3.)
V 1 . O A
T R A N S .
Press the [PAUSE] key.
Continued on Section 6.3.10
Ribbon Motor Drive Voltage
Fine Adjustment
6-29
(Revision Date Jun. 28, '96)
6.3 PARAMETER SETTING MODE
• Transmissive ribbon
Transmissive:
Non-transmissive: Ribbon end
• Non-Transmissive ribbon
Transmissive:
Non-transmissive: With ribbon
EM18-33012
With ribbon
Ribbon end