6. DIAG. TEST OPERATION
2) Parameters
#
(11)
Character code selection
Font zero selection
(12)
Control code selection
(13)
Ribbon type selection
(14)
Feed length fine adjustment
(19)
(PC), (KEY)
(15)
Cut/strip position fine adjustment
(20)
(PC), (KEY)
(16)
Back feed length fine adjustment
(21)
(PC), (KEY)
(17)
Print tone fine adjustment
(22)
(Thermal transfer) (PC), (KEY)
(18)
Print tone fine adjustment
(23)
(Thermal direct) (PC), (KEY)
(24)
X axis fine adjustment
(25)
Ribbon Motor
(26)
Strip wait status
(27)
Threshold manual fine
adjustment for the black mark
sensor
(28)
Threshold manual fine
adjustment for the feed gap
sensor
(29)
Kanji code type
(not supported by QQ/QP
models.)
(30)
Euro font code setting
(31)
Stacker
(not supported by QQ/QP
models.)
(32)
Transmission Control Mode
(33)
Reset Selection when the
INPUT.PRIME signal is on.
Item
PC-850
PC-8
0
Ø
AUTO
ESC LF NUL
{ }
1B 1C 1D
TRANS.
NON TRANS. : Non-transmissive ribbon
-50.0 mm to +50.0 mm
-50.0 mm to +50.0 mm
-9.9 mm to +9.9 mm
-10 step to +10 step
-10 step to +10 step
-99.5 mm to +99.5 mm
+15 step to +0 step
1: Strip wait status is not sent to the PC.
2: Strip wait status is sent to the PC.
0.0 V to 4.0 V
0.0V to 4.0 V
TYPE 1: Windows code
TYPE 2: Original code
20H to FFH
OFF: No stacker
ON: with stacker
DTR: READY/BUSY (DTR) protocol (DTR/DSR)
RTS: READY/BUSY (RTS) protocol (RTS/CTS)
ON: The printer will restore to the initial status.
OFF: The printer will not restore the initial status.
Contents
: PC-850
: PC-8
: No slash used.
: Slash used.
: Automatic selection
: ESC LF NUL mode
: Mainframe mode
: Manual mode
: Transmissive ribbon
6-5
EM18-33012
(Revision Date: Dec. 10 '99)
6.2 SELF TEST MODE