FEATURES

CONTROL PANEL FEATURES

1
1
Fuel Selector Switch: Select and turn on gas or
propane.
Push Button Electric Start:
2
• Push for 1 second to automatically start the engine.
• Push again to stop the engine.
3
Engine Control Switch/Battery Disconnect: Switch
to "Stop" to stop the engine. When in "Stop" position it
prevents the unit from drawing power from the battery.
Switch to "Run" before starting engine.
Main Circuit Breaker: The main circuit breaker controls
4
total output of all outlets to protect the generator.
5
120-Volt, 20-Amp Duplex GFCI Outlets
(NEMA 5-20R): Each outlet is capable of carrying
a maximum of 20 amps on a single receptacle or a
combination of both receptacles.
120/240-Volt, 30-Amp Twist Lock Outlet
6
(NEMA L14-30R): Outlet can supply either
120V or 240V output up to 30A.
120/240-Volt, 50-Amp Outlet (NEMA 14-50R):
7
Outlet can supply either 120V or 240V up
to 50 amps.
Smart Switch Outlet: Connects the Westinghouse ST
8
Switch (sold separately) to the control panel.
Battery Charge Port: Charge generators battery with
9
included charger.
10
Battery Indicator Light: When light is illuminated,
the battery is connected and providing power to the
electronics.
3
2
4
10
8
5
9
11
12
11
VFT Data Center: Press and release the mode
button to toggle between Voltage, Frequency,
Total Hour Meter and Run/Maintenance Timer.
Voltage
Frequency in hertz
Lifetime run hours
Run/Maintenance
The Run/Maintenance Timer displays the time in hours
and minutes each time the generator is ran. The run
timer resets to 00:00 when the generator is shut off.
Built into this run timer is a maintenance reminder.
When the new generator is ran for 25 hours, the meter
will display P25. This is to remind you to change the oil
after the initial 25 hours of run time. When it displays
P50, it is time to clean the air filter. When it displays
P100 it is time change/clean the fuel filter, clean the air
filter, and change the oil.
20-Amp Circuit Breakers: Each circuit breaker limits
12
the current that can be delivered through the 120-volt
duplex outlets to 20amps.
30-Amp Circuit Breakers: Each circuit breaker limits
13
the current that can be delivered through each 120-volt
leg of the L14-30R 30A outlet.
14
Ground Terminal: The ground terminal is used to
ground the generator.
Westinghouse Outdoor Power Equipment | 15
6
7
14
13