36
HYDRAULIC UNIT
B3-point Hitch Lowering Speed
To avoid personal injury:
A Fast lowering speed may cause damage or
injury. Lowering speed of implement should be
adjusted to two or more seconds.
The lowering speed of the 3-point hitch can be controlled
by adjusting the 3-point hitch lowering speed knob.
(1) 3-Point hitch lowering speed knob
(A) "FAST"
(B) "SLOW"
(C) "LOCK"

AUXILIARY HYDRAULICS

Hydraulic outlet is provided on the tractor.
BHydraulic Block Type Outlet
Hydraulic block type outlet is useful when adding
hydraulically operated equipment such as front end
loader, front blade, etc.
When implement is attached
1. Remove the block cover.
2. Attach the block outlet cover. (option)
(1) Block cover
(2) Block outlet cover (option)
(3) Outlet
(4) Inlet
(5) Hydraulic block
A For hydraulic block type outlet, be sure to use the
control valve of the "Power beyond type" with relief
valve that has a third line return to tank for the
operation of hydraulic block.
(A) From gear pump
(B) To implement inlet
Max. flow
15.1 L/min
No relief valve in the
hydraulic block.
(C) From implement outlet