Problem
Cause
The maintenance
There is a problem with the
wrench icon appears
inputs to the power meter.
in the power meter
display.
The meter is not receiving
The display is blank
adequate power.
after applying control
power to the meter.
Incorrect setup values
The data displayed is
Incorrect voltage inputs
inaccurate.
Power meter is wired
improperly.
Power meter address is
incorrect.
Power meter baud rate is
Cannot communicate
incorrect.
with power meter
Communications lines are
from a remote
improperly connected.
personal computer.
部件名称
Part Name
(Pb)
电子件
X
Electronic
本表格依据SJ/T11364的规定编制。
O: 表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规定的限量要求以下。
X: 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572规定的限量要求。
(企业可在此处,根据实际情况对上表中打
This table is made according to SJ/T 11364.
O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below
the limit as stipulated in GB/T 26572.
X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part
is above the limit as stipulated in GB/T 26572
Z000057-0B
©2018 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Other companies' trademarks are hereby acknowledged to belong to their respective owners.
See the Alert sub-menu or the Diagnostic Alert BACnet Binary_Input objects
Verify that the meter control power is receiving the required voltage.
Verify that the heart icon is blinking.
Check the fuse.
Verify the values entered for power meter setup parameters (CT and PT ratings,
system type, etc.). See the Setup section.
Check power meter voltage input terminals to verify adequate voltage.
Check all CTs and PTs to verify correct connection, PT polarity, and adequate power.
See the Wiring Diagrams section for more information.
Verify that the meter is correctly addressed. See the Setup section.
Verify that the baud rate of the meter matches that of all other devices on its
communications link (see Setup section).
Verify the power meter communications connections. See the Communications
section.
Verify the terminating resistors are properly installed on both ends of a chain of
units. Do not use a terminator on units in the middle of a chain.
Verify shield ground connection between all units.
Hazardous Substances
有害物质 -
(Hg)
(Cd)
(Cr (VI))
六价铬
O
O
O
的技术原因进行进一步说明。)
Solution
(PBB)
多溴联苯
多溴二苯醚
O
O
TM
(PBDE)
0818

Advertisement

Table of Contents
loading

This manual is also suitable for:

E50h2E50h5

Table of Contents