Part ID
CBL008
Flat ribbon cable, 50 x 28 AWG, 1.5 ft. (0.45 m)
CBL016
Flat ribbon cable, 50 x 28 AWG, 4 ft. (1.2 m)
CBL017
Flat ribbon cable, 50 x 28 AWG, 5 ft. (1.5 m)
CBL018
Flat ribbon cable, 50 x 28 AWG, 6 ft. (1.8 m)
CBL019
Flat ribbon cable, 50 x 28 AWG, 8 ft. (2.4 m)
CBL020
Flat ribbon cable, 50 x 28 AWG, 10 ft. (3.0 m)
CBL021
Flat ribbon cable, 50 x 28 AWG, 20 ft. (6.1 m)
CBL022
Round ribbon cable, 50 x 28 AWG, 4 ft. (1.2 m)
CBL023
Round ribbon cable, 50 x 28 AWG, 10 ft. (3 m)
CBL024
Round ribbon cable, 50 x 28 AWG, 20 ft. (6 m)
CBL025
Flat ribbon cable, 50 x 28 AWG, 2 m
CBL026
Flat ribbon cable, 50 x 28 AWG, 4 m
CBL027
Flat ribbon cable, 50 x 28 AWG, 6 m
CBL031
Round ribbon cable, 50 x 28 AWG, 1.5 ft. (0.45 m)
CBL032
Round ribbon cable, 50 x 28 AWG, 2.5 ft. (0.76 m)
AE001
E3xE MCB cover
Problem
Product is not communicating over
Modbus daisy chain
Power factor reading is not as expected
Current reading is not as expected, or
reading is on different CT number than
expected
Current is reading zero, even when small
currents are still flowing through circuit
E3xE Config Tool returns Modbus error on
read/write
部件名称
Part Name
(Pb)
电子件
X
Electronic
本表格依据SJ/T11364的规定编制。
O: 表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规定的限量要求以下。
X: 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572规定的限量要求。
(企业可在此处,根据实际情况对上表中打
This table is made according to SJ/T 11364.
O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below
the limit as stipulated in GB/T 26572.
X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part
is above the limit as stipulated in GB/T 26572
Z000057-0B
©2020 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Other companies' trademarks are hereby acknowledged to belong to their respective owners.
Description
• Check the unit Modbus address to ensure that each device on the daisy chain has a unique
address.
• Check Parity.
• Check the communications wiring.
• Check that the daisy chain is properly terminated.
• Verify voltage taps are connected in appropriate phase rotation.
• Verify strip configuration register matches actual strip installation.
• Verify phase rotation of breakers.
• Verify strip configuration register matches actual strip installation.
• Verify ribbon cable is fully seated and in the correct orientation.
• The product cuts off at 50 mA, and will set the reporting register to 0 mA for currents near or
below this range.
• Verify using the latest release of the NetConfig configuration software tool as older versions
may not support all features in current product firmware. Latest version is available on our
website http://www.veris.com/modbus.aspx