JUKI MO-6800S/DD20 Series Instruction Manual page 41

Table of Contents

Advertisement

No
Item
P086
Translucent fabric, correction of ma-
terial-detection threshold
P087
Standard fabric, correction of materi-
al-detection threshold
P088
Type of fabric
P089
Selection of check pattern fabric
P090
Front sensor, reaction time
P097
Number of products
J04
Selection of voice language
J05
Voice setting ON / OFF
J06
Voice volume setting
J10
Backlight brightness setting
J11
Backlight OFF time
J13
Counting method ON / OFF
Description
The correction value set with this function setting number applies to the threshold of detecting
in the case "1: Translucent fabric" is selected with the function setting number P088.
The correction value set with this function setting number applies to the threshold of detecting
in the case "2: Standard fabric" is selected with the function setting number P088.
This function setting number is used for selecting the type of fabric to be sewn in order to cor-
rect the sensors' threshold of detecting the material.
(0: Transparent fabric / 1: Translucent fabric / 2: Standard fabric)
This function setting number is used in the case the fabric with grid pattern holes. In the case
"DD22" is selected with the function setting number "P125 Model selection" (can be set in
the Service level), the value of "P033 Number of stitches to prevent cloth trimming" must be
changed from the initial value. (0: General fabric / 1: Check pattern fabric)
When the front sensor detects the presence of the material, the sewing machine's next oper-
ation is delayed by the time set with this function setting number. The smaller the value is set,
the earlier the reaction time becomes. (Unit: ms)
The number of finished products is counted with this function setting number (Unit: Piece)
It is necessary to set the counting method with the function setting number J13.
This function setting number is used for selecting the voice language.
(0: English / 1: Chinese / 2: Vietnamese / 3: Bengali / 4: Khmer / 5: Indonesian / 6: Turkish /
7: Korean / 8: Spanish / 9: Portuguese / 10: Italian / 11: French / 12: German / 13: Japanese)
* At the time of shipment from the factory, audio output is available only in "0: English" and "1:
Chinese". If you want to use any other language, it will be necessary to separately install the
relevant audio file. Refer to the Engineer's Manual for details.
* This parameter cannot be changed to the initial value that has been factory-set at the time of
shipment.
This function setting number is used for setting the voice guidance to ON or OFF.
(0: OFF / 1: ON)
This function setting number is used for setting the volume of the voice guidance.
(1: Small / 2: Medium / 3: Large)
* This parameter cannot be changed to the initial value that has been factory-set at the time of
shipment.
This function setting number is used for setting the brightness of the backlight.
(1: Dark / 2: Medium / 3: Bright)
This function setting number is used for setting the time to turn off the LCD backlight when the
operation panel is left not-operated. (0: Backlight is not turned off / 1 - 250: Time to be elapsed
until the backlight is turned off) (Unit: Minute)
This function setting number is used for setting the method to count the number of finished
products for "P097 Number of products". (0: OFF / 1: Ascending order / 2: Descending order / 3:
Ascending order (audio notification) / 4: Descending order (audio notification))
– 38 –
Initial value
Range
DD22
0-800
50
0-800
200
0-2
2
0-1
0
10-990
50
0000-9999
0000
0-13
0
0-1
1
1-3
2
1-3
3
0-250
30
0-4
0
DD23
50
200
2
0
50
0000
0
1
2
3
30
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mo-6800d/dd20 series

Table of Contents