JUKI MO-6800S/DD20 Series Instruction Manual page 40

Table of Contents

Advertisement

No
Item
P067
Presser foot lifting during sewing ON
/ OFF
P068
Presser foot lifting by depressing the
back part of foot pedal by half of its
depressing depth
P069
Front lifter, duration
P070
Rear lifter, starting time
P071
Presser foot lifting time
P072
Presser foot retaining DUTY
P073
Presser foot protection time
P076
Front sensor, irradiation intensity
P077
Intermediate sensor, irradiation in-
tensity
P078
Rear sensor, irradiation intensity
P079
Front sensor, material detection
threshold
P080
Intermediate sensor, material detec-
tion threshold
P081
Rear sensor, material detection
threshold
P085
Transparent fabric, correction of ma-
terial-detection threshold
Description
This function setting number is enabled when the sewing machine is operated with the foot
pedal (except for the full automatic mode). It is used for setting whether or not the presser foot
is automatically lifted when the foot pedal is returned to its neutral position. (0: OFF / 1: ON)
It is possible to select the type of presser foot lifting operation to be carried out when the back
part of the foot pedal is fully depressed or depressed by half of its depressing depth.
(0: Lifting the presser foot by depressing the back part of pedal by half-depth or by fully de-
pressing the back part of pedal / 1: Lifting of the presser foot is OFF / 2: Lifting the presser foot
by fully depressing the back part of pedal)
This function setting number is enabled when the function setting number P066 is set to "1:
Front lifter" or "3: Front and rear lifters". It is used for setting the time that elapses from lifting to
lowering of the presser foot. (Unit: ms)
This function setting number is enabled when the function setting number P066 is set to "2:
Rear lifter" or "3: Front and rear lifters". It is used for setting the delay time that elapses before
the presser foot lifting operation starts. (Unit: ms)
The presser foot lifting time should be entered when the solenoid valve is used. It is an extend-
ed parameter for future use. (Not used)
This function setting number is used for setting the time during which the presser foot lifter is
held in the ON state. (Unit: s)
It is possible to adjust the output intensity of the front sensor (light projecting side). (Unit: %)
* This parameter cannot be changed to the initial value that has been factory-set at the time of
shipment.
It is possible to adjust the output intensity of the intermediate sensor (light projecting side).
(Unit: %)
* This parameter cannot be changed to the initial value that has been factory-set at the time of
shipment.
This function setting number is enabled only in the case "DD23" is selected with the function
setting number "P125 Model selection".
It is possible to adjust the output intensity of the rear sensor (light projecting side). (Unit: %)
* This parameter cannot be changed to the initial value that has been factory-set at the time of
shipment.
This is the threshold of detecting the presence / absence of the material with the front sensor.
* This parameter cannot be changed to the initial value that has been factory-set at the time of
shipment.
This is the threshold of detecting the presence / absence of the material with the intermediate
sensor.
* This parameter cannot be changed to the initial value that has been factory-set at the time of
shipment.
This function setting number is enabled only in the case "DD23" is selected with the function
setting number "P125 Model selection".
This is the threshold of detecting the presence / absence of the material with the rear sensor.
* This parameter cannot be changed to the initial value that has been factory-set at the time of
shipment.
The correction value set with this function setting number applies to the threshold of detecting
in the case "0: Transparent fabric" is selected with the function setting number P088.
– 37 –
Initial value
Range
DD22
DD23
0-1
0
0-2
0
50-2000
500
0-2000
120
10-990
50
10-90
20
1-120
5
0-100
80
0-100
80
0-100
80
0-700
300
0-700
300
0-700
375
0-800
10
0
0
500
120
50
20
5
80
80
80
300
300
375
10