Dimension Of Connecting Pipe; Connection Of Branch Pipe - Gree SUPER+MULTI ULTRA Series Installation & Owner's Manual

R410a systems-outdoor unit
Table of Contents

Advertisement

Super Free Match Series
6.2
Dimension
of Connecting Pipe
Outdoor unit
Between outdoor unit and the
1st branch
Between the 1st and the 2nd
branch

6.3 Connection of Branch Pipe

1)
If two or three BU modules used, Y-type branch pipe of FQ01A/A will be chosen.
FQ01A/A (Liquid pipe)
2)
Y-type branch pipe is equipped with auxiliary tubes to adjust the diameter of different pipes. If
the dimension of the pipe selected is different from the dimension of branch pipe joint, Cut the
copper tube in the middle with tube cutter and clear up burrs. Please do that as following figure.
3)
Y-type branch pipe must be installed in vertical or horizontal direction. In the inlet of the branch
pipe, keep at least 500mm straight pipe.
Table 4
Sorts
MULTIU48HP230V1BO
The pipe L1
The pipe L2
Fig. 9
Fig. 10
Fig. 11
10
Gas Pipe
Liquid Pipe
(mm/inch)
(mm/inch)
Φ15.9(5/8)
Φ9.52(3/8)
Φ19.05(3/4)
Φ9.52(3/8)
Φ15.9(5/8)
Φ9.52(3/8)
FQ01A/A (Gas pipe)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multiu48hp230v1boGwhdhd3doGwhd48shd3do