Parts And Components Of Unit; Working Temperature Range - Gree SUPER+MULTI ULTRA Series Installation & Owner's Manual

R410a systems-outdoor unit
Table of Contents

Advertisement

3.3 Parts and Components of Unit

For the super free match series, one outdoor unit is able to drive up to three BU modules and
nine indoor units which include cassette type, duct type, wall mounted type, floor ceiling type and
console type. The outdoor unit will run as long as any one indoor unit receives the running command,
and all indoor units stop once the outdoor unit is turned off.
Power supply wire for outdoor
unit and BU module(3 wires)
Connection pipe
Transmission line(2 wires)
Power supply wire for
indoor unit(4 wires)
Outdoor unit
Ground

3.4 Working Temperature Range

Sorts
Maximum cooling
Minimum cooling
Maximum heating
Minimum heating
Ground
(60Hz, 208/230V)
Ground
The 2nd
branch
(60Hz, 208/230V)
Ground
The 1st
branch
(60Hz, 208/230V)
Power
(60Hz, 208/230V)
BU 3
Power
BU 2
Power
BU 1
Power
Fig. 2
Table 2
Outside temperature:DB(℃/℉)
54℃(129℉)
10℃(50℉)
27℃(81℉)
-35℃(-31℉)
5
Super Free Match Series
Indoor unit
Duct type
Wall mounted
type
Floor ceiling
type
Console type
Wall mounted
type
Cassette type
Cassette type
Duct type
Wall mounted
type

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multiu48hp230v1boGwhdhd3doGwhd48shd3do