Configuring The Adtran Esbc; Step 1: Access The Esbc Cli - ADTRAN eSBC Interoperability Manual

Table of Contents

Advertisement

Integrating ADTRAN eSBC and NEC SV8100
Equipment and Versions
The following table outlines the equipment and firmware versions used in verification testing.
Table 1. Verification Test Equipment and Firmware Versions
ADTRAN Total Access 908e with eSBC
NEC SV8100 PBX
NEC PCPro Management Software
NEC DT700 IP Phone, ITL-6DE-1
NEC DT700 IP Phone, ITL-12D-1
NEC DT700 IP Phone, ITL-320C-2

Configuring the ADTRAN eSBC

The following sections describe the key configuration settings required for this solution. These settings are
implemented using the ADTRAN Operating System (AOS) command line interface (CLI).
To configure the ADTRAN eSBC for interoperability with the NEC SV8100 PBX, follow these steps:

Step 1: Access the eSBC CLI

The AOS unit can be managed using the console port, Hypertext Transfer Protocol (HTTP), HTTP Secure
(HTTPS), Telnet, and Secure Shell (SSH). Most of the initial configuration is performed through the
console port or Telnet session. Accessing the AOS unit is described in this step.
To access the CLI on your AOS unit, follow these steps:
1. Boot up the unit.
2. Telnet to the unit (telnet <ip address>), for example:
telnet 10.10.10.1.
6AOSSG0027-42A
Product
Copyright © 2015 ADTRAN, Inc.
Configuring the ADTRAN eSBC
Firmware Version
R10.9.6
06.00
1.03.0n.pipk
5.0.3.0
5.0.2.0
5.0.2.0