2. Overview

This product is PROFIBUS communication module that can be used in a PROFIBUS network.

2.1. Specification

Module specifications
Item
Type-form
Applicable inverter
Connector
Supported network
Indicator
Protection degree
Environments
Network specifications
Baud rate
Cyclic communication
PROFIBU
S
Acyclic communication
Configuration
I&M
Response time
*Response time is the time until the inverter is operated by RUN command on the cyclic communication
Item
Specification
PDP003Z
VF-MB1
VF-S15 with SBP009Z
VF-AS3
9 pin D-sub
PROFIBUS V0, V1
2 LEDs indicating the Status and the Data exchange.
IP20
Correspond to inverter.
12Mbit/s, 6Mbit/s, 3Mbit/s, 1.5Mbit/s, 500kbit/s,
187.5kbit/s, 93.75kbit/s, 19.2kbit/s, 9.6 kbit/s,
45.45 kbit/s (Only for the VF-AS3)
PROFIdrive V.4.1 (Telegram1)
4PKW and 2 PZD vendor format (Telegram100)
4PKW and 6 PZD vendor format (Telegram101)
6 PZD vendor format (Telegram102)
Reading the PROFIdrive parameter
Reading/writing the inverter parameters
Configured by PROFIBUS master
I&M function 0
*Cyclic communication About 10ms
- 7 -
E6581738④