Toshiba TOSVERT VF-MB1 Function Manual page 37

Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

fc91 (Alarm code)
7.5.16.
VF-S15/MB1
bit
0
Over-current alarm
1
Inverter over load alarm
2
Motor over load alarm
3
Over heat alarm
4
Over voltage alarm
5
Main circuit undervoltage alarm
6
main device overheat alarm
7
Under current alarm
8
Over-torque alarm
9
Braking resistor overload alarm
10
Cumulative operation hours alarm
11
Option communication alarm
12
Serial communication alarm
13
MOFFMS (MS-relay off or MOFF)
14
Stop after instantaneous power off
15
Stop after LL continuance time
VF-AS3
bit
0
Over-current alarm
1
Inverter over load alarm
2
Motor over load alarm
3
Overheat alarm
4
Overvoltage alarm
5
(Undefined)
6
Inverter overheat alarm
7
Undercurrent alarm
8
Over-torque alarm
9
Braking resistor overload alarm
10
Cumulative run time alarm
11
Communication option alarm
12
Serial communication alarm
13
Power circuit under voltage alarm
14
Stop after instantaneous power off
15
During sleep
Function
Function
- 35 -
0
1
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Dec., Under
-
stop
Dec., Under
-
stop
0
1
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
-
-
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Dec., Under
-
stop
Dec., Under
-
stop
E6581738④
Remarks
(Code displayed on
the panel)
c flicking
l flicking
l flicking
h flicking
p flicking
-
l flicking
-
-
-
-
-
-
-
Refer to f302
value
Refer to f256
value
Panel display
[c] flicking
[l] flicking
[l] flicking
[h] flicking
[p] flicking
-
[l] flicking
-
-
-
-
[t] flicking
[t] flicking
[moff] flicking
[stop] flicking
[stop] flicking

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tosvert vf-s15Tosvert vf-as3

Table of Contents