AIR-EAGLE
2.4GHz RF Transceiver
MODEL 36-40400-DC
DESCRIPTION
The A
-E
SR PLUS TRX is an R.F. transceiver capable of
IR
AGLE
transmitting and receiving commands from up to 600 feet away. This
model comes equipped with four dry contact inputs and four 5amp
relay outputs. When combined with another transceiver this allows the
user to transmit information out and receive a confirming signal back
that the operation was performed. This unit has eight user-selectable
network frequencies to allow multiple systems to operate
simultaneously in the same area without interference.
APPROVALS
United States (FCC)
Canada (IC)
Europe (CE)
INSTALLATION
DISCONNECT AC Power from all equipment before installation.
1.
Mount the A
-E
XLT TRANSCEIVER in a convenient location.
IR
AGLE
Install input & output wiring to the terminal strip (Note – terminal strip
2.
header lifts off base for easy wiring)
3.
Install antenna to TNC connector on the right side of the enclosure.
4.
Connect supplied power input cable to your external power source.
TERMINAL STRIP WIRING
INPUTS
1
Common Input 1
9
2
Input 1
10
3
Common Input 2
11
4
Input 2
12
5
Common Input 3
13
6
Input 3
14
7
Common Input 4
8
Input 4
Terminal #1
Terminal #2
105 Bonnie Drive
Butler, PA 16002
724-283-4681
724-283-5939 (fax)
www.bwieagle.com
®
SR PLUS
OUR-XBEEPRO
4214A-XBEEPRO
ETSI
OUTPUTS
N/O Relay #1
15 N/O Relay #3
C Relay #1
16 C Relay #3
N/C Relay #1
17 N/C Relay #3
N/O Relay #2
18 N/O Relay #4
C Relay #2
19 C Relay #4
N/C Relay #2
20 N/C Relay #4
DC INPUT
(-) 9-36VDC Input
(+) 9-36VDC Input
PRODUCT INFORMATION
BULLETIN
GENERAL OPERATION
Contact closures on inputs 1 thru 4 in the control transceiver transmit
to activate relay #1 thru #4 in the remote transceiver. Inputs from the
remote equipment provide closures to remote transceiver that transmit
to energize relays #1 thru #4 in the control transceiver.
INPUT
ACTION
ACTIVATED
"1"
Transmits channel 1 command to remote unit
"2"
Transmits channel 2 command to remote unit
"3"
Transmits channel 3 command to remote unit
"4"
Transmits channel 4 command to remote unit
INPUT CODE
ACTION
RECEIVED
"1"
Relay #1 energizes, maintained momentary
"2"
Relay #2 energizes, maintained momentary
"3"
Relay #3 energizes, maintained momentary
"4"
Relay #4 energizes, maintained momentary