Specification
Specification
Output
Flue gas temperature (rated heating output, wood)
Flue gas temperature
(rated heating output, oil)
Flue gas mass flow rate
(rated heating output, wood)
Max. draught, wood
*1
Required chimney draught
Output
Flue gas temperature (rated heating output, wood)
Flue gas temperature
(rated heating output, oil)
Flue gas mass flow rate
(rated heating output, wood)
Max. draught, wood
*1
Required chimney draught
Maximum overpressure during the start phase (chimney cold) in the flue pipe downstream of the flue gas fan
*1
No draught limiter required
*2
72
*2
*2
kW
40
°C
180
°C
168
g/s
30.4
Pa
25
Pa
10
kW
85
°C
180
°C
172
g/s
58.4
Pa
25
Pa
10
50
60
180
180
168
168
35.2
44
25
25
10
10
100
120
180
180
172
168
72
88
25
25
10
10
75
180
168
56
25
10
170
180
168
108
25
10