Fujitsu PRIMERGY RX200 S5 Operating Manual page 12

Rack server
Hide thumbs Also See for PRIMERGY RX200 S5:
Table of Contents

Advertisement

Preface
Features
Hard disk drives
The server can be equipped with a maximum of 6 (variant with DVD slot) or
8 SAS/SATA HDD modules.
Each HDD module can accommodate an SAS/SATA hard disk drive with a
maximum height of 1 inch. The module is connected to the SAS/SATA
backplane wirelessly. This allows HDD modules to be plugged in or pulled out
easily.
Four SATA hard disk drives can be controlled by the onboard SATA controller.
To control further SATA hard disk drives, an additional RAID controller must be
installed.
SAS hard disk drives require an additional RAID controller.
Hybrid configurations of SAS and SATA HDD modules are not supported.
If the server has the corresponding RAID configuration, HDD modules can also
be replaced during operation.
Onboard SATA controller
A 6-port SATA controller is integrated on the system board; up to four SATA hard
disk drives can be connected to the controller. The LSI Embedded MegaRAID
software (SATA Software RAID) supports RAID levels 0, 1 and 10.
For more information on configuring the controller, see section
"Configuring the
onboard SATA controller" on page
67.