INSTALLATION
9.3.2
Installing the diaphragm safety valve
– Pressurised connection:
»
Install the diaphragm safety valve in the cold water supply line; see chapter "Installation / Installation
location".
»
Observe the information in the installation instructions of the diaphragm safety valve.
9.3.3
Mounting the screw hooks
»
Mark out the holes to be drilled in accordance with the dimensioned drawings; see chapter "Specifica-
tion / Dimensions and connections".
»
Drill both holes and then insert rawl plugs.
»
Screw in both screw hooks.
9.3.4
Installing the appliance
»
Hang the appliance onto the screw hooks.
»
Secure the water connections from the tap to the appliance.
9.3.5
Adjusting the flow rate
By adjusting the flow rate, the limits regarding appliance and tap noise can be adhered to. In addition
there will be a minor mixing effect and consequently the stored hot water can be used more efficiently.
– Pressurised connection:
»
Set a maximum flow rate of 12 l/min at the cold water supply to the appliance.
– Unpressurised connection:
»
Set a maximum flow rate of 12 l/min at the tap (see tap description).
9.3.6
Connecting the power supply
Risk to life through electrocution!
Carry out all electrical connection and installation work in accordance with regula-
tions.
Risk to life through electrocution!
» Installation with direct (permanent) power cables is not permitted.
» An earthed socket is required. This socket must be freely accessible after the appli-
ance has been installed.
» Where the appliance is to be connected permanently to the AC power supply (junc-
tion box for the appliance), ensure that all poles can be separated from the power
supply with a contact separation of at least 3 mm.
Risk of damage
!
Observe the type plate. The specified voltage must match the mains voltage.
Earth connection.
Ensure that the appliance is earthed.
10

COMMISSIONING

Risk to life through electrocution!
Commissioning must only be carried out by an authorised contractor in accordance
with safety regulations.
42
EN