English
OPERATION
3
APPLIANCE DESCRIPTION
The appliance constantly keeps the water content available at the preselected temperature.
The DHW outlet temperature can be variably adjusted according to preference at the temperature selector.
The output is switched on automatically as soon as the appliance temperature falls below the selected
value.
– Pressurised connection:
The appliance is under mains water pressure. The volume of water expands as the
water heats up. During this process, expansion water drips through the safety valve.
This is a necessary and normal process.
– Unpressurised connection:
The volume of water expands as the water heats up. Expansion water drips through
the tap outlet. This is a necessary and normal process.
4
OPERATION
4.1
Temperature selector
You can select whichever temperature you require at the temperature selector.
The ON/OFF indicator illuminates while the water is being heated.
1
Temperature selector
Fully turned to the left "Frost protection"
"E" approx. 60 °C
Fully turned to the right approx. 80 °C
2
Indicator
4.2
Frost protection
The water heater is equipped with a frost protection stage. For this, fully turn temperature selector to the
left (cold). In this position, the water heater is protected against frost. The tap and the water line are not
protected.
4.3
Economy setting
The appliance has an economy setting "E". At this setting, minor scaling inside the appliance will occur.
4.4
Heat-up time / Outlet volume
See chapter "Specification / Data table".
2
1
EN
37