Bunn TITAN DUAL Service & Repair Manual page 9

Table of Contents

Advertisement

TROUBLESHOOTING (cont.)
PROBLEM
Water flows into tank continuously
with power removed from brewer.
RELEASED FOR PRODUCTION
PROBABLE CAUSE
1. Refill valve
2. Refill probe or sensitivity setting
3. Control Board
DIR Num: 41747.0000
Page 9
12, December 2018
REMEDY
Foreign material lodged in valve,
holding it in open state.
Check the sensitivity setting. Refer
to the REFILL function in Program-
ming Manual. If the left three digit
number is less than the right num-
ber, the machine "thinks" it is full and
the refill valve should be off. If the
left number is larger than the right,
then the refill valve will automatically
be turned on to fill the tank. The right
number is the threshold setting and
can be adjusted to compensate for
extreme water conditions: very pure,
low conductance water requires a
higher setting, while high mineral
content, high conductance water
requires a lower setting. Note that
the left number changes from a high
value when water is NOT touching
the refill probe to a low valve when
water IS touching the probe. For
best operation, the right number
should be set to a value midway
between these low and high num-
bers. Before changing the setting,
confirm that the refill probe is free
of scale buildup and the connection
to it is secure.
Substitute a control board known
to be in good working order.
41747 112608

Advertisement

Table of Contents
loading

This manual is also suitable for:

Titan single