Midea M2OC-18HFN1-M Service Manual page 70

Table of Contents

Advertisement

9.4.2.6 E6(PFC module protection) error diagnosis and solution. (Only for M4OC-36HRFN1-M)
Error Code
Malfunction decision
conditions
Supposed causes
Trouble shooting:
PFC module protection
Check whether the
connecting line between
main board and the PFC
module is connected tightly
Yes
Check whether the voltage
range of P-N on IPM
module is normal? DC277-
356V for 18-27KBtu/h;
DC277-410V for 36KBtu/h
No
Check
whether
inductance of PFC module
is good? If the inductance is
good, the resistance of the
two ports is 0
Yes
Replace the PFC module
E6
When the voltage signal that PFC sends to main control board
is abnormal, the display LED will show "E6" and AC will turn
off.
● Wiring mistake
● Outdoor PCB faulty
● Inductance of PFC module faulty
PFC module malfunction
Connect it tightly, check
No
No
Replace the outdoor main board
Yes
the
No
Replace the inductance
normal or not
Trouble is solved
Yes

Advertisement

Table of Contents
loading

Table of Contents