9.2 Indoor Unit Error Display

Vertu series & Luna series:
Display
E0
Indoor EEPROM malfunction
E1
Communication malfunction between indoor and outdoor units
E2
Zero-crossing signal error
E3
Indoor fan speed has been out of control
E5
Open circuit or short circuit of outdoor temperature sensor or outdoor EEPROM malfunction
E6
Open circuit or short circuit of T1 or T2 temperature sensor
P0
IPM module protection or IGBT over-strong current protection
P1
Voltage protection
P2
Temperature protection of compressor top
Outdoor temperature is lower than -15° C (optional function)
P3
P4
Inverter compressor drive protection
P5
Mode conflict
Console series
Operation
Timer
X
X
X
X
X
X
X
Failure
De-frost
X
Open or short circuit of T1 temperature sensor
Open or short circuit of T2 temperature sensor
X
Communication malfunction between indoor and outdoor units
X
Indoor EEPROM malfunction
Outdoor fan speed has been out of control
IPM module protection
Open or short circuit of T3 or T4 temperature sensor or Outdoor unit
EEPROM parameter error
X
Temperature protection of compressor top
X
Inverter compressor drive protection
Mode conflict
Indoor fan speed has been out of control
★ flash at 5Hz,  light, X extinguished, ◎flash at 0.5Hz
ODU Error code
Failure
——
E2
——
——
E0,E4
——
P6
E5
P0
——
——
——