Testing the thermostat.
Once the thermostat is installed, it should be thoroughly tested.
CAUTION!
the outdoor temperature is below 50 degrees. This can damage
the air conditioning system.
Note: Before testing the thermostat, move the Fan Auto/On switch
to the Auto position.
Fan Test
1. With Function switch set to Off, slide Fan
Auto/On switch to On position.
2. Indoor fan turns on.
3. Slide Fan Auto/On switch to Auto position.
4. Indoor fan turns off.
Cool Test
1. Slide Function switch to Cool position.
Cool mode screen is displayed.
2. Adjust set temperature so it is 5 degrees
below room temperature.
3. Air conditioning should come on within a few seconds.
4. Adjust the set temperature so it is 2 degrees above the
room temperature and the A/C should turn off. Note: There
is a 3 minute time delay and a 3 minute minimum run time
for the compressor when it turns on/off. (On some models,
the fan may also have a minimum run time/off time delay).