Rosslare HLX-24TH Series User Manual page 22

Advanced wireless security panels
Table of Contents

Advertisement

User Menu Structure
Select
Zone Bypass
Remote Controls
(M) Private
Numbers
Walk Test
22
To
Enables you to arm the system by bypassing/un-bypassing
selected zones (see Section 8.8).
This option is enabled if manual bypass has been enabled by the
installer.
Note: Zone bypass can be triggered only if the zone was
enrolled.
Enroll remote controls for quick activation of the system (see
Section 8.9)
Specify up to three private telephone numbers (see Section
8.11).
When entering the detector's Test mode, the red and green
LEDs on the panel flash every second simultaneously, and the
display shows "receiving...".
If the alert monitoring station reporting options is enabled, an
E607 event is transmitted.
The Walk Test sequence timeout is for 15 minutes. In the last 5
minutes, a squawk is heard every two seconds in addition the
green and red LEDs flash simultaneously to indicate that the
testing period will be terminated in another five minutes.
If the system walk detector test is terminated, an R607 restore
event is transmitted (if enabled).
During the Walk Test, each successful detector violation causes
a squawk and the signal strength is displayed.
In the conclusion of the Walk Test, the installer may browse
through the recorded results by using the Menu button. Each
browsing of a record is followed by the E613 event transmission
with the relevant zone indication.
For 24-H and fire zones, reporting trouble event E380 is sent to
the monitoring station.
HLX-24 User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HLX-24TH Series and is the answer not in the manual?

Table of Contents