Download Print this page
AmeriWater VARIABLE SPEED PUMP SYSTEM Operation & Maintenance Manual

AmeriWater VARIABLE SPEED PUMP SYSTEM Operation & Maintenance Manual

Advertisement

Quick Links

VARIABLE SPEED PUMP SYSTEM
OPERATION & MAINTENANCE MANUAL
Manufactured With Pride
In The USA
www.ameriwater.com • 800-535-5585
AmeriWater • 3345 Stop 8 Rd. • Dayton, OH 45414
P/N 98-0034 Rev.B
5NOV09

Advertisement

loading
Need help?

Need help?

Do you have a question about the VARIABLE SPEED PUMP SYSTEM and is the answer not in the manual?

Questions and answers

Summary of Contents for AmeriWater VARIABLE SPEED PUMP SYSTEM

  • Page 1 VARIABLE SPEED PUMP SYSTEM OPERATION & MAINTENANCE MANUAL Manufactured With Pride In The USA www.ameriwater.com • 800-535-5585 AmeriWater • 3345 Stop 8 Rd. • Dayton, OH 45414 P/N 98-0034 Rev.B 5NOV09...
  • Page 2 TABLE OF CONTENTS: VARIABLE SPEED PUMP SYSTEM INTRODUCTION……….…1 SYSTEM DESIGN DRAWING……………………………………….….2 GOULDS AquaBoost II CONTROLLER………………………….….3 GOULDS AquaBoost II CONTROLLER IMPORTANT SAFETY INSTRUCTIONS.…………………………………………...4-5 MOUNTING THE CONTROLLER………………………………….…..5 POWER SUPPLY & WIRING – CONTROLLER…………………….6 STARTING THE SYSTEM (AMP SETTINGS & PRESSURE SETTINGS) – CONTROLLER……………………………………….…..7 STARTING THE SYSTEM (APPLICATION SWITCHES, MOTOR ROTATION) –...
  • Page 3: Theory Of Operation

    The variable speed pump controls out going variable pressures of the water for better equipment operation by maintaining a constant pressure on the system. The variable speed pump system is controlled by the AquaBoost II Controller, Model 2AB2 (6.9A). The AquaBoost II is a self-diagnosing controller.
  • Page 9 Note The Motor Overload Switch is set when the Variable Speed Pump System is built. It should be checked periodically. The DIP Switch Setting has been set at (1011) for a 5.8 AMP Motor.
  • Page 10 A Blinking Green Status Code indicates that the pump is running. A Blinking or Solid Red Light Indicates a problem with the controller. Refer to the access cover side panel or Diagram 6 for Status Codes. See Troubleshooting Section on pages 11 & 12 for more details.
  • Page 13 Note See the Pump’s Trouble Shooting Chart on page 18 in reference to the Controller’s Trouble Shooting Indicator Code, Status & Description.
  • Page 20 NOTE: See the AquaBoost Controller’s Trouble Shooting Indicator Code, Status & Description on pages 11 & 12 in reference to the Pump’s Trouble Shooting Chart.
  • Page 23 (PVC). The AmeriWater system you have purchased may contain PVC or stainless steel parts. While warnings are only required in the State of California, AmeriWater has initiated the use of Prop 65 labeling for all products to ensure compliance with California regulations. Please note that the above warning does not necessarily mean that the product that you have purchased is unsafe.