FIXTURE INSTALLATION

FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft (1.5m) away from any flammable materials, decoration,
pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installa-
tions.
ADDITIONAL PRECAUTIONS:
For added protection, mount the fixture outside of walking paths, seating areas, or areas were
unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 5°F to 113°F (-15°C to 45°C). Do not
operate the fixture when ambient temperatures fall outside of this range.
Before mounting the fixture to any surface, make sure the installation area can hold a minimum
point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment, such as an
appropriately rated safety cable.
Never stand directly below the device when mounting, removing, or servicing.
POWER LINKING
Max number of units that can be power linked is as follows:
• 6 units @110V.
• 15 units @240V.
CLAMP MOUNTING
The SIXBAR 1000™ includes integrated dual floor stand/rigging yokes. When mounting this fixture to
a truss, be sure to secure appropriately rated clamps to the yokes using a M10 screw fitted through
the center hole.
SAFETY CABLE
Always use a safety cable (not included) whenever installing this fixture in a suspend-
ed environment to ensure that the fixture will not drop if the clamp fails.