Error Codes - Inalto IDW7CS User Manual

60cm freestanding dishwasher
Hide thumbs Also See for IDW7CS:
Table of Contents

Advertisement

Error Codes

If there is a malfunction the dishwasher will display error codes to identify the fault.
Code Indicator
Meanings
E1 will be displayed
Water entering the dish-
on the LED display
washer has exceeded the
and the buzzer will
pre-set time, or the flow of
sound.
water into the dishwasher is
restricted.
E3 will be displayed
The dishwashers on board
on the LED display
sensors have detected that
and the buzzer will
the water isn't reaching the
sound.
desired temperature within
the pre-set time.
E4 will be displayed
Overflow. The onboard com-
on the LED display
puter has detected a leak
and the buzzer will
(correctly or incorrectly).
sound.
E6 will be displayed
Potential component failure.
on the LED display
and the buzzer will
sound.
E7 will be displayed
Potential component failure.
on the LED display
and the buzzer will
sound.
WARNING! If the E4 Overflow error is occurring, turn off the main water supply at the tap as a pre-caution, before
calling our Customer Care team.
Note. If there is water in the base of the dishwasher because of an overfill or small leak, the water should be
removed before re-starting the dishwasher.
Possible Causes
Ensure that the water supply hose is un-kinked and that
the water supply tap is fully open.
Potential malfunction of the heating element. Try turning
the appliance power off at the power point for 15 minutes
before re-starting.
Also ensure the filter system is clean and free of foreign
objects (such as broken glass).
Check the drain hose isn't kinked or blocked.
If issue persists, please contact our Customer Care team.
Check that your dishwasher is level, an un-level dishwash-
er can trigger this alarm.
If the problem persists Contact our Customer Care team.
Try turning the appliance power off at the power point for
15 minutes before re-starting.
If issue persists, please contact our Customer Care team.
Try turning the appliance power off at the power point
for 15 minutes before re-starting. If issue persists, please
contact our Customer Care team.