Air Supply; Solvent Selection - Uni-ram UG2000DM Series User Manual

Automatic spray gun cleaners
Hide thumbs Also See for UG2000DM Series:
Table of Contents

Advertisement

MANUAL - UG2000DM SERIES SPRAY GUN CLEANERS
LOCATION
Position the unit in a well-ventilated area away from sparks, heat and open flames, at least 6 " from the
back wall.

AIR SUPPLY

Connect a male air supply adapter (not supplied) into the female Air Inlet on the unit. The male air
supply adapter is 1/4" NPT.
Connect the female air supply hose to the adapter. The air supply hose must be at least 3/8"
The air supply pressure must be at least 85 PSI and the sup-
inside diameter.
ply air must be free from contaminants such as water, dust, rust, tar and
grease. If the air supply is not clean and dry install a moisture filter. The
operation and longevity of the pump and other components depends on
clean dry supply air.
To prevent damage to the Diaphragm Pump an internal Air Pressure Regulator has been
installed to limit the air pressure to 85 PSI. Do not install a second air pressure regulator or use a
pressure set below 85 PSI.
GROUNDING
Connect the green ground wire at the back of the unit to a ground in the building.
Note: The pump and metal tube that inserts into each pail are grounded.

SOLVENT SELECTION

The adhesion quality of automotive paint has dramatically improved in recent years. The choice of sol-
vent is critical. Only use good quality solvent that is formulated for your paint and intended for use with
automatic spray guns cleaners. DO NOT USE CHLORINATED SOLVENT.
PAIL SETUP
Place the suction hose and drain hose in the solvent pail.
Open the drain valve (vertical position).
Pour 5 gallons of solvent in the wash tank to drain to the wash pail underneath.
DRAIN VALVE IS OPEN
(HANDLE IN VERTICAL POSITION)
Ring Terminal
DRAIN VALVE IS CLOSED
(HANDLE IN HORIZONTAL POSITION).
.
4
REVISED 2018-12

Advertisement

Table of Contents
loading

Table of Contents