Mc-Ip-116 Connections - Tech Works MC-IP Series Manual

Modular communication internet protocol audio intercommunication
Table of Contents

Advertisement

MC-IP-116 Connections

All system components employ RJ45 connectors for a couple of purposes
1. For connection of Tech Works PA-Buss components such as the PA-402
2. For connection of components to the IP Network
Either application assumes standard off the shelf CAT6 cables wired to EIA/TIA 568B
Power connections are on both the Euro Style Screw Block and the
5.50mm OD (0.217") Barrel connector for 24 VDC.
Screw terminal power connections are always:
External Paging Amplifier connections are always:
Station field wiring is a 4 or 6-conductor compression clamp connector with 0.1 inch spacing and will
connect to 18-24 AWG wire. Wires must be stripped of insulation approximately ¼ inch from the end
before being inserted in the connector. A slot above each connection allows the insertion of a 2.0 mm
tech blade screw driver to release the clamp so that you can remove the wire if necessary.
Remote Station connections are:
SPEAKER (+)
SPEAKER (
CALL SWITCH
LED POWER (+)
LED POWER (
1/24/2021
Tech Works MC-IP-Series System Planning & Installation Manual
-
)
SHIELD
If this is an MC-IP-116-L there will be
-)
2 additional terminals
2.00mm ID (0.079"),
Page 12 of 32