Temperature warning
A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message.
This warning is issued by ServerView when the ambient temperature exceeds
the upper limit of the temperature boundaries. The upper limit is 35°C for
standard server and 40°C or 45°C with Advanced Thermal Design.
Cause
The ambient
temperature exceeds
the upper limit of the
temperature
boundaries
Added drive reported as defective
Cause
RAID controller is not
configured for this
drive
TX1330 M4
Troubleshooting
Ê Although continued use within the temperature
boundaries poses no problems within itself,
reconsider the surrounding environment
conditions if this log is output or if ServerView
issues this notification.
Troubleshooting
The drive was probably installed when the system
was switched off.
Ê Reconfigure the RAID controller for the drive
using the corresponding utility. Information is
provided in the documentation for the RAID
controller.
or
Ê Remove and reinstall the drive while the system is
switched on.
If the HDD/SSD continues to be shown as
defective, then replace it (see the "FUJITSU
Server PRIMERGY TX1330 M4 Server Upgrade
and Maintenance Manual").