This function will allow you to link up to 16 units together and operate them without a controller. The
units will be sound activated. In this type of set up, one unit will act as the controlling unit and the
others will react to the controlling units programs. Any unit can act as a Primary or as a Secondary.
1. Using approved DMX data cables, daisy chain your units together via the XLR connector on the
rear face of each unit. Remember the Male XLR connector is the input and the Female XLR con-
nector is the output. The first unit in the chain (primary) will use the female XLR connector only,
and the last unit in the chain will use the male XLR connector only. For longer cable runs, the
installation of a terminator on the last fixture is highly recommended.
2. Set the Primary unit to your desired operating mode.
3. On the Secondary units tap the MENU button until "SCND" is displayed, and press ENTER.
4. Choose either "SEC1" or "SEC2" and press ENTER. See the System Menu section of this manu-
al for more info.
5. The Secondary units will now follow the Primary unit.
Inno Pocket Scan
This fixture can be linked to multiple other fixtures of the same model type using the IEC input and
output sockets.
The maximum number of fixtures that can be linked in this manner is as follows:
19 fixtures maximum for 120V
35 fixtures maximum for 240V
Once this number has been reached, a new power outlet must be used in order to accommo-
date any additional fixtures.
All linked fixtures must be of the same make and model type. DO NOT mix fixtures.