5.
WATER CONNECTIONS
5.1
DRINKING WATER CONNECTION
Before connecting the appliance, flush the water pipes and
fittings and clean out any dirt.
The appliance is designed for connection to fixed lines.
Metal installation pipes may not protrude more than 10 cm
from the floor or the wall.
The maximum water pipe pressure must not exceed 6 bar
(600 kPa).
A mechanical filter, a shutoff valve and a non-return valve
should be built into the customer fresh water feed pipe.
In general, all national and local water regulations must be
observed.
The appliance is to be connected to the sanitation system
in accordance with the valid installation connection plans
and diagrams.
5.1.1
FREE-STANDING INSTALLATION
The water connections come up from the floor.
Make corresponding openings in the base of the frame to
lead the hoses through.
Remove front panel (B) (siehe Kapitel 2.1).
Dismantle the storage space or hot cabinet if necessary.
Connect the flexible hoses (5), with a G ½" inside thread,
with or without fitting a stop valve, to the customer-supplied
water pipes protruding from the floor.
5.1.2
FITTING AGAINST A WALL
The water connections come up from the floor or out of the
wall. For floor connection (siehe Kapitel 5.1.1).
Pull the flexible hoses (5) out of the open rear wall and con-
nect to the customer-provided water pipes protruding from
the wall with a G ½" inside thread, with or without fitting a
stop valve.
Position the appliance against the wall.
5.2
WASTE WATER
The appliance outlet pipe must be taken through a sufficiently
large waste water opening.
Note
Ensure accurate measurement of the waste water collcting
point and the exact positioning of the appliance.
62.9680.01
INSTALLATION INSTRUCTIONS
Seite 19