Installation Instructions - Electrolux thermaline S90 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

II . INSTALLATION INSTRUCTIONS
1.
INSTALLATION
The appliance is designed for connection to fixed lines. The
appliances are suitable for setting up as single appliances or as
a group of appliances. They can be set up freely in the room,
side by side, at the side and/or at the back against a wall.
1.1
DISTANCES
If an appliance is set up next to or against temperature-sensi-
tive furniture or similar, a safety gap of approximately 50 mm
should be maintained or some form of heat insulation fitted.
When setting up an appliance in the close vicinity of walls, par-
titions, kitchen equipment, decorative cladding, etc., it is
recommended that the latter are made of incombustible mate-
rial or that they are clad in a suitable, incombustible material.
The regulations governing fire protection must be adhered to
as closely as possible.
1.2
HEIGHT ADJUSTMENT
Appliance on feet: Alignment is carried out by screwing the
lower foot parts in or out.
Appliance on
Irregularities or differences in height can
steel plinth:
be equalized by inserting one or several
strips of chrome nickel steel.
Appliance on
Alignment is carried out by placing metal
masonry plinth:
plates under the appliance..
1.3
ASSEMBLING TWO APPLIANCES
(1)
a
c
Fig.1 Lateral connection
The assembly kit contains two of each of the following:
caged nuts (1 / Fig.1) pre-assembled on the right-hand side of
the appliance, hexagonal screws M8x25 (1 / Fig.1) and moun-
ting links (2 / Fig.1)
62.9680.01

INSTALLATION INSTRUCTIONS

(3a)
(1)
(2)
(3b)
(1)
(2)
(2)
(3c)
b
(3c)
1
Remove the control panels from both appliances as in 2.2
Remove the front panels from both appliances as in 2.1
Keeping the screw (1 / Fig.1) loose, turn it until it is approxi-
mately 5 mm deep in the caged nut.
Positioning the appliances:
Place the appliances next to one other.
Align for position and height.
Connect the appliances:
Fit the mounting link (2 / Fig.1) into the inside of the second
appliance's left connecting plate.
Tighten the screws.
Note
If required, the caged nuts can also be fitted on the other side
of the appliance.
1.4
SIDEWALL (D)
()
(5)
(4)
1
a
Fig.2 Assemblage of sidewall
The assembly kit contains two of each of the following:
hexagonal screws M8x25 (1 / Fig.1), bolts with retaining rings
(2 / Fig.1), mounting links (3 / Fig.1), hexagonal screws M8x16
with serrated washers and hexagonal nuts M8, hexagonal
screws M5 with serrated washers (4 / Fig.2)
and a fastening angle (5 / Fig.2).
Insert the bolts with the retaining rings (2 / Fig.1a) from out-
side into the guide in the sidewall.
Keeping the screw (1 / Fig.1a) loose, turn it until it is
approximately 5 mm deep in the pre-assembled caged
nuts in the sidewall.
Attach the fastening angle (5 / Fig.2b) to the bottom of the
frame using the screws, serrated washers and nuts.
(4 / Fig.2).
Position the sidewall and screw it on from below using two
hexagonal screws and the serrated washers.
Fit the mounting link (3 / Fig.1b) into the inside of the appli-
ance's connecting plate.
Align the sidewall and firmly tighten all screws.
(3c)
1
b
Seite 15

Advertisement

Table of Contents
loading

Table of Contents