High gearmotor amps – Stage 2
If the restart is successful the board will continue to monitor the current draw on P4 for 60 minutes looking for a
second high amps (above 1 .8A) or no current draw (0A) occurrence . If the ice machine runs without problems for
60 minutes and no additional torque errors occur, the ice machine will continue normal operation .
T.O.L.
RED
Start
Relay
4
3
2
YELLOW
BLACK
R
S
C
Gearmotor
A B C D
Water Sensors
High gearmotor amps – Stage 3
If a second occurrence happens during the 60 minute monitoring period, the HI AMPS LED will come on again
and shut the machine down (strike two) . The HI AMPS LED (without the TIME DELAY LED) will indicate to the
technician that two consecutive over-torque situations have occurred . The ice machine is shut down at this time
and locked out . It will not restart unless the manual reset button is depressed while power is on .
T.O.L.
RED
Start
Relay
4
3
2
YELLOW
BLACK
R
S
C
Gearmotor
A B C D
Water Sensors
R
S
C
Compressor
2
1
Start
Relay
5
Compressor
Electrical Box
WHITE
Drain
Fill
Valve
Valve
Bin T-Stat
R
S
C
Compressor
2
1
Start
Relay
5
Compressor
Electrical Box
WHITE
Drain
Fill
Valve
Valve
Bin T-Stat
Fan
WHITE
N
N
P15
L1
BLACK
L1
HI PRS
RED
P6
P21
P20
BROWN
P19
BLACK
P3
WATER LEVELS
P22
BLUE
P4
AUGER
Fan
WHITE
N
N
P15
L1
BLACK
L1
HI PRS
RED
P6
P21
P20
BROWN
P19
BLACK
P3
WATER LEVELS
P22
BLUE
P4
AUGER
E12CI425A 230 V 50 Hz, C12CI425A 220 V 60 Hz
High
Pressure
Switch
POWER
LOW BIN
MAKING ICE
SLEEP CYCLE
TIME DELAY
LOW WATER
1 2 3 4 5 6 7 8
MAINTENANCE
RESET
SERVICE
HI AMPS
HI PRESSURE
P11
BIN
CLEANER FULL
Clean Switch
High
Pressure
Switch
POWER
LOW BIN
MAKING ICE
SLEEP CYCLE
TIME DELAY
1 2 3 4 5 6 7 8
LOW WATER
MAINTENANCE
RESET
SERVICE
HI AMPS
HI PRESSURE
BIN
P11
CLEANER FULL
Clean Switch