Ice and water dispensers 230 v 50 hz, 220 v 60 hz
Table of Contents

Advertisement

Quiet Night™/Sleep cycle
The board monitors ice dispensing through a line voltage input to P15 . If the ice dispense has not be initiated for
more than 5 seconds during the 20 minute time delay, the SLEEP CYCLE LED comes on . The machine will stay off
for 12 hours unless 5 seconds of dispensing is seen . After 12 hours, the SLEEP CYCLE LED goes out and the ice
making will resume if the bin thermostat is closed . The sleep cycle dispense duration is adjustable using the DIP
switches on the control board .
Self-flushing
At the completion of the 20 minute time delay, the machine checks for a cumulative one hour of ice making time
since the last off-cycle flush . If the cumulative ice making time exceeds one hour, the machine will energize the
drain valve P19 for 60 seconds to drain the evaporator . It will then refill with water, flush again, refill and begin
making ice if the LOW BIN LED is on . If the ice making time is less than 1 hour, the machine will start and begin
making ice without draining the evaporator .
T.O.L.
RED
Start
Relay
4
2
3
YELLOW
BLACK
R
S
C
Gearmotor
A B C D
Water Sensors
R
S
C
Compressor
2
1
Start
Relay
5
Compressor
Electrical Box
WHITE
Drain
Fill
Valve
Valve
Bin T-Stat
Fan
WHITE
N
N
P15
L1
BLACK
L1
HI PRS
RED
P6
P21
P20
BROWN
P19
BLACK
P3
WATER LEVELS
P22
BLUE
P4
AUGER
E12CI425A 230 V 50 Hz, C12CI425A 220 V 60 Hz
High
Pressure
Switch
POWER
LOW BIN
MAKING ICE
SLEEP CYCLE
TIME DELAY
1 2 3 4 5 6 7 8
LOW WATER
MAINTENANCE
RESET
SERVICE
HI AMPS
HI PRESSURE
P11
BIN
CLEANER FULL
Clean Switch
27