9.4.2 Maximum Nulling

9.4.2
9.4.2
9.4.2
Maximum Nulling
Maximum Nulling
Maximum Nulling
Using the Down navigational arrow move the cursor in front of "Max Out". Press
the Enter button and using the navigational arrow move the cursor under the
last digit.
The conveyor should now be turning.
Using the navigational arrows adjust the spinner speed to the maximum speed
required during the spreading operation.
The reading on the screen is % of maximum controller output allowed,
permitting the spinner motor to operate to this maximum speed only.
Press the Enter button to return the cursor in front of the Max reading.
Press the Escape button once to return to the previous screen.
9.4.3
9.4.3

Auto Nulling

Auto
Nulling
9.4.3
9.4.3
Auto
Auto
Nulling
Nulling
Auto nulling of the spinner is possible only if the spinner is equipped with a speed
sensor.
9.5

Positive Placement System

9.5.1
9.5.1
Setting the Spinner Sp

Setting the Spinner Speed Sensor "Pulses per Revolution"

9.5.1
9.5.1
Setting the Spinner Sp
Setting the Spinner Sp
Insert the programming key, select "SENSORS AND VALVES", select "SPINNER
SETUP" and select "SPINNER SENSOR". The screen to the left will appear.
Determine the "pulses per Revolution" from the manufacturer's specifications.
Use the Up or Down navigation button to move the cursor in front of "0022
Pulses/Rev" and press the Enter button.
Using the Left or Right navigation button, move to the number to be changed.
Using the Up or Down navigation button, change the number as required.
Once all the numbers have been changed, press the Enter button.
Press the Escape button three times to return to the first screen.
9.5
9.5.2 .2 .2 .2 Setting the Spinner

Setting the Spinner Maximum RPM

9.5
9.5
Setting the Spinner
Setting the Spinner
Insert the programming key, select "SENSORS AND VALVES", select "SPINNER
SETUP" and select "VALVE SETTING". The screen to the left will appear.
Determine the hydraulic motor's maximum speed from the manufacturer's
specifications.
Use the Down navigation button to move the cursor in front of "0500 – Max
RPM" and press the Enter button.
Using the Left or Right navigation button move to the number to be changed.
Using the Up or Down navigation button, change the number as required.
Once all the numbers have been changed, press the Enter button.
Press the Escape button three times to return to the first screen.